X9522
VTRIPX (X = 1,2) PROGRAMMING PARAMETERS (See Figure 24)
Parameter
Description
tVPS
tVPH
tTSU
tTHD
tVPO
VTRIPx Program Enable Voltage Setup time
VTRIPx Program Enable Voltage Hold time
VTRIPx Setup time
VTRIPx Hold (stable) time
VTRIPx Program Enable Voltage Off time
(Between successive adjustments)
twc
VTRIPx Write Cycle time
VP
Programming Voltage
Vta
VTRIPx Program Voltage accuracy
(Programmed at 25°C.)
Vtv
VTRIP Program variation after programming (-40 - 85°C).
(Programmed at 25°C.)
Min
10
10
10
10
1
10
-100
Typ Max
5
10
15
+100
Units
µs
µs
µs
µs
ms
ms
V
mV
-25
+10 +25
mV
Notes: These parameters are not 100% tested.
V2RO, V3RO OUTPUT TIMING. (See Figure 23)
Symbol
tRPDx(4)
tFx(4)
tRx(4)
VRVALID(4)
Description
V2, V3 to V2RO, V3RO propagation
delay (respectively)
V2, V3 Fall Time
V2, V3 Rise Time
Vcc / V1 for V2RO, V3RO Valid (3).
Condition
Min.
20
20
1
Typ.
Max.
20
Units
µs
mV/µs
mV/µs
V
Notes: 1. See Figure 23 for timing diagram.
Notes: 2. See Figure 18 for equivalent load.
Notes: 3. This parameter describes the lowest possible Vcc / V1 level for which the outputs V2RO, and V3RO will be correct with respect to their
inputs ( V2, V3).
Notes: 4. The above parameters are not 100% tested.
23
FN8208.0
March 10, 2005