POTENTIOMETER CHARACTERISTICS
Symbol
RTOL
VRHx
VRLx
Parameter
End to End Resistance Tolerance
RH Terminal Voltage (x = 0,1,2)
RL Terminal Voltage (x = 0,1,2)
PR
Power Rating (1)(6)
RW
DCP Wiper Resistance
IW
Wiper Current(6)
Noise
Absolute Linearity (2)
Relative Linearity (3)
RTOTAL Temperature Coefficient
CH/CL/CW
twr
VTRIP
tPU
Potentiometer Capacitances
Wiper Response time(6)
Vcc / V1 power-up DCP recall
threshold
Vcc / V1 power-up DCP recall delay
time(6)
Limits
Min. Typ. Max. Units
Test Conditions/Notes
-20
+20
%
Vss
Vcc /
V1
V
Vss
Vcc /
V1
V
10
mW
RTOTAL = 10kΩ (DCP0,
DCP1)
5
mW RTOTAL = 100kΩ (DCP2)
200 400
IW = 1mA, Vcc / V1 = 5 V,
Ω
VRHx = Vcc / V1, VRLx = Vss
(x = 0,1,2).
IW = 1mA, Vcc / V1 = 2.7 V,
400 1200
Ω
VRHx = Vcc / V1, VRLx = Vss
(x = 0,1,2)
4.4 mA
mV/ RTOTAL = 10kΩ (DCP0,
sqt(Hz) DCP1)
mV/
sqt(Hz)
RTOTAL = 100kΩ (DCP2)
-1
+1
MI(4) Rw(n)(actual) - Rw(n)(expected)
-1
+1
MI(4) Rw(n+1) - [Rw(n) + MI]
±300
ppm/°C
RTOTAL = 10kΩ (DCP0,
DCP1)
±300
10/10/25
ppm/°C RTOTAL = 100kΩ (DCP2)
pF See Figure 19.
200
µs See Figure 25.
V
25
50
75
ms
Notes: 1. Power Rating between the wiper terminal RWX(n) and the end terminals RHX or RLX - for ANY tap position n, (x = 0,1,2).
Notes: 2. Absolute Linearity is utilized to determine actual wiper resistance versus, expected resistance = (Rwx(n)(actual) - Rwx(n)(expected)) = ±1
Ml Maximum (x = 0,1,2).
Notes: 3. Relative Linearity is a measure of the error in step size between taps = RWx(n+1) - [Rwx(n) + Ml] = ±1 Ml (x = 0,1,2)
Notes: 4. 1 Ml = Minimum Increment = RTOT / (Number of taps in DCP - 1).
Notes: 5. Typical values are for TA = 25°C and nominal supply voltage.
Notes: 6. This parameter is periodically sampled and not 100% tested.
22
FN8208.0
March 10, 2005