English
Language : 

X40420 Datasheet, PDF (15/25 Pages) Xicor Inc. – Dual Voltage Monitor with Integrated CPU Supervisor and System Battery Switch
X40420, X40421
ABSOLUTE MAXIMUM RATINGS
Temperature under bias .................... -65°C to +135°C
Storage temperature ......................... -65°C to +150°C
Voltage on any pin with
respect to VSS ...................................... -1.0V to +7V
D.C. output current ............................................... 5mA
Lead temperature (soldering, 10 seconds) ........ 300°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
-40°C
Max.
70°C
+85°C
Version Chip Supply Voltage
-A or -B
2.7V to 5.5V
-C
2.7V to 5.5V
*See ordering Info
Monitored
Voltages*
2.6 to 5.5V
1.6V to 3.6V
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified)
Symbol
ICC1(1)
ICC2(1)
ISB1(1)(7)
Parameter
Active Supply Current (VCC) Read
(Excludes IOUT)
Active Supply Current (VCC) Write Non
Volatile Memory (Excludes IOUT)
Standby Current (VCC) AC (WDT off)
ISB2(2)(7) Standby Current (VCC) DC (WDT on)
IBATT1(3)(7) VBATT Current (Excludes IOUT)
IBATT2(7) VBATT Current (Excludes IOUT)
(Battery Backup Mode)
VOUT1(7)
VOUT2(7)
VOLB
VOHB
VBSH(7)
Output Voltage (VCC > VBATT + 0.03V or
VCC > VTRIP1)
Output Voltage (VCC < VBATT – 0.03V and
VCC < VTRIP1) {Battery Backup}
Output (BATT-ON) LOW Voltage
Output (BATT-ON) HIGH Voltage
Battery Switch Hysteresis
(VCC < VTRIP1)
ILI
Input Leakage Current (SCL, MR, WP)
ILO Output Leakage Current (SDA, V2FAIL,
WDO, RESET)
VIL(3)
VIH(3)
Input LOW Voltage (SDA, SCL, MR, WP)
Input HIGH Voltage (SDA, SCL, MR, WP)
Min.
Typ.(5)
Max.
1.5
3.0
Unit Test Conditions
mA VIL = VCC x 0.1
VIH = VCC x 0.9,
mA fSCL = 400kHz
6
25
0.4
VCC-0.05V
VCC-0.5V
VBATT-0.2
10
µA VIL = VCC x 0.1
VIH = VCC x 0.9
fSCL, fSDA = 400kHz
30
µA VSDA = VSCL = VCC
Others = GND or VCC
1
µA VOUT = VCC
6
µA VBATT = 2.8V
VOUT = Open
V IOUT = 5mA (4.5-5.5V)
IOUT = 50mA (4.5-5.5V)
V IOUT = 250µA
VOUT-0.8
-0.5
VCC x 0.7
0.4
V IOL = 3.0mA (4.5-5.5V)
V IOH = -0.4mA (4.5-5.5V)
30
mV Power-up
-30
Power-down
10
µA VIL = GND to VCC
10
µA VSDA = GND to VCC
Device is in Standby(2)
VCC x 0.3 V
VCC + 0.5 V
15
March 28, 2005