English
Language : 

X5163S8IZT1 Datasheet, PDF (14/22 Pages) Intersil Corporation – Selectable watchdog timer
X5163, X5165
AC Electrical Specifications Serial Output Timing(Over operating conditions unless otherwise specified.)
2.7-5.5V
SYMBOL
PARAMETER
MIN
MAX
UNIT
fSCK
Clock Frequency
0
2
MHz
tDIS
Output Disable Time
250
ns
tV
Output Valid from Clock Low
200
ns
tHO
Output Hold Time
0
ns
tRO(3)
Output Rise Time
100
ns
tFO(3)
Output Fall Time
100
ns
NOTES:
3. This parameter is periodically sampled and not 100% tested.
4. tWC is the time from the rising edge of CS after a valid write sequence has been sent to the end of the self-timed internal nonvolatile write cycle.
CS
SCK
SO
tCYC
tWH
tLAG
tV
MSB OUT
tHO
MSB–1 OUT
tWL
tDIS
LSB OUT
SI
ADDR
LSB IN
TABLE 3. SERIAL OUTPUT TIMING
VCC
0 Volts
VTRIP
tR
RESET (X5163)
tPURST
tPURST
VTRIP
tF
tRPD
RESET (X5165)
TABLE 4. POWER-UP AND POWER-DOWN TIMING
Submit Document Feedback 14
FN8128.4
August 13, 2015