X9430 Datasheet, PDF (12/21 Pages) Xicor Inc. – Dual Digitally Controlled Potentiometer (XDCP™) with Operational Amplifier
X9430
POTENTIOMETER D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC1 VCC supply current (active)
ICC2 VCC supply current (nonvolatile
write)
ISB
VCC current (standby)
ILI
Input leakage current
ILO
Output leakage current
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL Output LOW voltage
Min.
Limits
Typ. Max.
400
1
VCC x 0.7
-0.5
1
10
10
VCC + 0.5
VCC x 0.1
0.4
Unit
µA
mA
µA
µA
µA
V
V
V
Test Conditions
fSCK = 2MHz, SO = Open,
Other Inputs = VSS
fSCK = 2MHz, SO = Open,
Other Inputs = VSS
SCK = SI = VSS, Addr. = VSS
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Unit
Data changes per register
years
CAPACITANCE
Symbol
COUT(5)
CIN(5)
CL | CH | CW
Test
Output capacitance (SO)
Input capacitance (A0, A1, SI, WP, HOLD and SCK)
Potentiometer capacitance
Typ.
10/10/2
Max.
8
6
Unit
pF
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
POWER-UP TIMING
Symbol
tPUR(6)
tPUW(6)
Parameter
Power-up to initiation of read operation
Power-up to initiation of write operation
Max.
1
5
Unit
ms
ms
A.C. TEST CONDITIONS
Input pulse levels
Input rise and fall times
Input and output timing level
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
SPICE Macro Model
RTOTAL
RH
RL
CH
CW
CL
Notes: (5) This parameter is periodically sampled and not 100%
tested.
(6) tPUR and tPUW are the delays required from the time the
third (last) power supply (VCC, V+ or V-) is stable until
RW
the specific instruction can be issued. These parameters
are periodically sampled and not 100% tested.
(7) The power-up order of power supplies are VCC, V+
and V-.
12
FN8198.0
March 11, 2005