English
Language : 

X9430 Datasheet, PDF (11/21 Pages) Xicor Inc. – Dual Digitally Controlled Potentiometer (XDCP™) with Operational Amplifier
X9430
AMPLIFIER ELECTRICAL CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Symbol
VOS
TCVOS
IB
IOS
CMRR
PSRR
VCM
AV
VO
IO
IS
GB
SR
ΦM
Parameter
Input Offset Voltage
Input Offset Voltage Temp.
Coefficient
Input bias current
Input offset current
Common mode
rejection ratio
Power supply
rejection ratio
Input common mode
voltage range
Large signal voltage gain
Output voltage swing
Output current
Supply current
Gain-bandwidth prod
Slew rate
Phase margin
Condition
V+/V- ±3V to ±5V
V+/V- ±3V to ±5V
V+/V- ±3V to ±5V
V+/V- ±3V to ±5V
VCM = -1V to +1V
V+/V- ±3V to ±5V
Tj = 25°C
VO = -1V to + 1V
V-
V+
V+/V- = ±5.5V
V+/V- = ±3.3V
V+/V- = ±5.0V
V+/V- = ±3.0V
RL = 100k, CL = 50pf
RL = 100k, CL = 50pf
RL = 100k,
CL = 50pf
Industrial
Min. Typ. Max.
1
3
-10
Commercial
Min. Typ. Max.
1
2
-10
Unit
mV
µV/°C
50
50
pA
25
25
pA
70
70
dB
70
70
dB
V-
V+ V-
V+
V
30 50
30 50
V/mV
+0.1
+0.1
-.15
V
-.15
V
50
50
mA
30
30
mA
3
3
mA
1.5
1.5
mA
1.0
1.0
MHz
1.5
1.5
V/µsec
80
80
Deg.
V+ and V- (±5V to ±3V) are the amplifier power supplies. The amplifiers are specified with dual power supplies. VCC
and VSS are the logic supplies. All ratings are over the temperature range for the Industrial (-40 to + 85°C) and
Commercial (0 to 70°C) versions of the part unless specified differently.
11
FN8198.0
March 11, 2005