English
Language : 

SMFL283R3S_10 Datasheet, PDF (8/15 Pages) Interpoint Corporation Company – Operating temperature -55° to +125°C Qualified to MIL-PRF-38534 Class H and K
Crane Aerospace & Electronics Power Solutions
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
Electrical Characteristics: -55°C to +125°C Tc, 28 VDC Vin, 100% load, RHA level O, unless otherwise specified.
DUAL output models 2
PARAMETER
CONDITIONS
OUTPUT VOLTAGE
VIN 16 TO 40 VDC
OUTPUT CURRENT 2, 3
VIN 16 TO 40 VDC
OUTPUT POWER 2
+VOUT
-VOUT
EACH OUTPUT
TOTAL
Vin = 16 to 40 VDC
OUTPUT RIPPLE
LINE REGULATION
VIN 16 TO 40 VDC
LOAD REGULATION
NO LOAD TO FULL
10 kHz - 2 MHz ± VOUT
+VOUT
-VOUT
+VOUT
-VOUT
CROSS REGULATION
TC = 25°C
SEE NOTE 4
SEE NOTE 5
INPUT VOLTAGE
+VOUT
TRANSIENT 120 ms 1, 6
SMFL2805D
MIN TYP MAX
4.85 5.00 5.15
4.82 5.00 5.18
0
—
7
0
—
10
0
—
50
—
50
100
—
0
50
—
25
100
—
0
50
—
25
100
—
5
8
—
3
6
16
28
40
—
—
50
SMFL2812D
MIN TYP MAX
11.64 12.00 12.36
11.58 12.00 12.42
0
—
3.5
0
—
5
0
—
60
—
50
120
—
0
50
—
25
100
—
0
50
—
50
120
—
2
4
—
2
4
16
28
40
—
—
50
SMFL2815D
MIN TYP MAX
14.55 15.00 15.45
14.47 15.00 15.53
0
—
3.03
0
—
4.33
0
—
65
—
50
150
—
0
50
—
25
100
—
0
50
—
150 150
—
2
4
—
2
4
16
28
40
—
—
50
UNITS
VDC
A
W
mV p-p
mV
mV
%
VDC
V
INPUT CURRENT
NO LOAD
—
50
120
—
50
100
—
50
100
INHIBITED–INH1
—
9
14
—
9
14
—
9
14
mA
INHIBITED–INH2
—
35
70
—
35
70
—
35
70
INPUT RIPPLE CURRENT
10 kHz - 10 MHz
—
30
50
—
30
50
—
30
80
mA p-p
EFFICIENCY
BALANCED LOAD
LOAD FAULT
TC = 25°C
75
78
—
81
84
—
82
85
—
%
TC = -55°C TO +125°C
73
—
—
79
—
—
80
—
—
SHORT CIRCUIT
POWER DISSIPATION
—
12.5
18
—
10
16
—
10
16
W
STEP LOAD RESPONSE 7
± VOUT
STEP LINE RESPONSE 1, 7
± VOUT
START-UP 9
CAPACITIVE LOAD 10
RECOVERY 1
50% - 100% - 50%
TRANSIENT
RECOVERY 1, 8
16 - 40 -16 VDC
TRANSIENT
RECOVERY 8
DELAY
TC = 25°C
—
1.5
4.0
—
1.5
4.0
—
1.5
4.0
ms
— ±250 ±350 — ±450 ±600 — ±500 ±600 mV pk
—
1.5
3.0
3.0
1.5
3.0
1.5
3.0
ms
— ±250 ±300 — ±250 ±400 — ±250 ±500 mV pk
—
200 300
—
200 300
—
200 300
µs
—
3.5
6
—
3.5
6
—
3.5
6
ms
—
—
500
­—
—
500
—
—
500
µF
Notes
1. Guaranteed by design, not tested.
2. Parallel load share function is not characterized for dual output models.
3. Up to 70% of the total output power is available from either output providing the
opposite output is simultaneously carrying 30% of the total power.
4. Effect on negative Vout from 50%/50% loads to 70%/30% or
30%/70% loads.
5. Effect on negative Vout from 50%/50% loads to 50% then 10% load on negative
Vout.
6. Unit will shut down above approximately 45V but will be undamaged and will
restart when voltage drops into normal range.
7. Transition time 100 µs ±20%.
8. Recovery time is measured from application of the transient to point at which Vout
is within 1% of final value.
9. Tested on release from inhibit.
10. Shall not compromise DC performance.
www.craneae.com/interpoint
Page 8 of 15
SMFL Rev K - 20101209