SMFL283R3S_10 Datasheet, PDF (2/15 Pages) Interpoint Corporation Company – Operating temperature -55° to +125°C Qualified to MIL-PRF-38534 Class H and K | |||
|
◁ |
Crane Aerospace & Electronics Power Solutions
SMFL Single and Dual DC/DC Converters
28 Volt input â 65 Watt
sharing mode, one SMFL converter is designated as a master.
The SLAVE pin (pin 11) of the master is left unconnected and the
MSTR/INH2 pin (pin 12) of the master is connected to the SLAVE
pin (pin 11) of the slave units. The units designated as slaves
have the MSTR/INH2 pin (pin 12) connected to the SNS RTN pin
(pin 9). Note that synchronizing the units together is not required
for current sharing operation.â
A second slave unit may be placed in parallel with a master and
slave; this requires the TRI pin (pin 3) of the master unit to be
connected to the SNS RTN pin (pin 9). See Figure 2 for a block
diagram of parallel connections.
When paralleled, 76% of the total combined power ratings of the
SMFL converters are available at the load. Overload and short
circuit performance are not adversely affected during parallel
Âoperation.
Operating Conditions and characteristics
Input Voltage Range
⢠16 to 40 VDC continuous
⢠50 V for 120 ms transient
Output Power
⢠40 to 65 watts depending on model
Lead Soldering Temperature (10 sec per lead)
⢠300°C
Storage Temperature Range (Case)
⢠-65°C to +150°C
Power Dissipation (Pd)
⢠14 watts (16 watts SMFL2805S, SMFL2805D)
Case Operating Temperature (Tc)
⢠-55°C to +125°C full power
Derating Output Power/Current
⢠Linearly from 100% at 125°C to 0% at 135°C
⢠MFL283R3S: linearly from 100% at 100°C
to 85% at 125°C to 0% at 135°C
Output Voltage Temperature Coefficient
⢠100 ppm/°C typical
Input to Output Capacitance
⢠150 pF, typical
Current Limit
⢠125% of full load typical
Isolation
⢠100 megohm minimum at 500 V
Audio Rejection
⢠50 dB typical
Conversion Frequency (-55°C to 125°C)
⢠Free run mode 600 kHz typical
â£â£ 5 25 kHz. min, 675 kHz max
Sync and inhibit (inh1, inh2)
Sync
⢠Sync In
â£â£Input frequency 525 to 675 Hz.
â£â£Duty cycle 40% min, 60% max
â£â£Logic low 0.8 V max
â£â£Logic high 4.5 V min, 5 V max
â£â£Referenced to input common
⢠Sync Out
â£â£Referenced to input common
Inhibit (INH1, INH2)
⢠Active low (output disabled)
â£â£INH1 referenced to input common
-- Active low 0.8 V max
-- Inhibit pin current 10 mA max
â£â£INH2 referenced to output common
-- Active low 0.5 V max
-- Inhibit pin current 5 mA max
⢠Active high (output enabled)
â£â£Open collector (output enabled)
â£â£Avoid intermediate voltages of 1.5 to 10.5
â£â£Open pin voltage
-- INH1 = 9 to 12 V
-- INH2 = 9 V max
mechanical and environmental
Size (maximum)
⢠3.005 x 1.505 x 0.400 inches (76.33 x 38.23 x 10.16 mm
See case U for dimensions.
⢠Case option V is also available.
Weight (maximum)
⢠86 grams
Screening
Space Prototype (O), Class H, or Class K are radiation tolerant
to Radiation Hardness Assurance (RHA) levels of â-â (O), âP,â
or âR,â per MIL-STD-38534. Interpoint model numbers use an
âOâ in the RHA designator position to indicate the â-â (dash)
Radiation Hardness Assurance level of MIL-PRF-38534, which is
defined as âno RHAâ.
See Screening Tables 1 - 3 for more information. Available
configurations: OO, HP, KP, HR, KR
www.craneae.com/interpoint
Page 2 of 15
SMFL Rev K - 20101209
|
▷ |