English
Language : 

SMFL283R3S_10 Datasheet, PDF (6/15 Pages) Interpoint Corporation Company – Operating temperature -55° to +125°C Qualified to MIL-PRF-38534 Class H and K
Crane Aerospace & Electronics Power Solutions
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
Electrical Characteristics: -55°C to +125°C Tc, 28 VDC Vin, 100% load, RHA level O, unless otherwise specified.
single output models
SMFL283R3S
SMFL2805S
PARAMETER
CONDITIONS
MIN TYP MAX
MIN
TYP MAX
OUTPUT VOLTAGE
3.21 3.30 3.39
4.87
5.00 5.13
OUTPUT CURRENT
Vin = 16 to 40 VDC
0
— 12.12
0
—
10
OUTPUT POWER
Vin = 16 to 40 VDC
0
—
40
0
—
50
OUTPUT RIPPLE
10 kHz - 2 MHz
LINE REGULATION
LOAD REGULATION
TC = 25°C
—
10
35
—
15
35
TC = -55°C TO +125°C
—
10
50
—
30
50
VIN = 16 TO 40 VDC
—
0
20
—
0
20
NO LOAD TO FULL
—
—
40
—
—
20
INPUT VOLTAGE
CONTINUOUS
16
28
40
16
28
40
TRANSIENT120 ms 1,2
—
—
50
—
—
50
INPUT CURRENT
NO LOAD
—
70
100
—
70
120
INHIBITED – INH1
—
9
14
—
9
14
INHIBITED – INH2
—
35
70
—
35
70
INPUT RIPPLE
10 kHz - 10 MHz
—
30
50
—
30
50
EFFICIENCY
LOAD FAULT
TC = 25°C
71
—
­—
TC = -55°C TO +125°C
69
—
—
SHORT CIRCUIT
POWER DISSIPATION
—
12.5
16
RECOVERY 1
1.5
6
75
78
—
73
—
—
—
12.5
18
1.5
4
STEP LOAD RESPONSE
50% - 100% - 50%
TRANSIENT
— ±200 ±300
—
±250 ±350
RECOVERY 1, 3
—
1.5
3.0
—
1.5
3.0
STEP LINE
RESPONSE 1, 3
16 - 40 -16 VDC
TRANSIENT 4
— ±250 ±300
—
±250 ±300
START-UP 5
Capacitive Load 6
RECOVERY
DELAY
TC = 25°C
—
200 300
—
—
3.5
10
—
—
— 1000
—
200 300
3.5
6
— 1000
Notes
1. Guaranteed by design, not tested.
2. Unit will shut down above approximately 45 V but will be undamaged and will
restart when voltage drops into normal range.
3. Recovery time is measured from application of the transient to point at
which VOUT is within 1% of final value.
4. Transition time 100 µs ±20%.
5. Tested on release from inhibit.
6. Shall not compromise DC performance.
UNITS
VDC
A
W
mV p-p
mV
mV
VDC
V
mA
mA p-p
%
W
ms
mV pk
ms
mV pk
µs
ms
µF
www.craneae.com/interpoint
Page 6 of 15
SMFL Rev K - 20101209