SMFL283R3S_10 Datasheet, PDF (6/15 Pages) Interpoint Corporation Company – Operating temperature -55° to +125°C Qualified to MIL-PRF-38534 Class H and K | |||
|
◁ |
Crane Aerospace & Electronics Power Solutions
SMFL Single and Dual DC/DC Converters
28 Volt input â 65 Watt
Electrical Characteristics: -55°C to +125°C Tc, 28 VDC Vin, 100% load, RHA level O, unless otherwise specified.
single output models
SMFL283R3S
SMFL2805S
PARAMETER
CONDITIONS
MIN TYP MAX
MIN
TYP MAX
OUTPUT VOLTAGE
3.21 3.30 3.39
4.87
5.00 5.13
OUTPUT CURRENT
Vin = 16 to 40 VDC
0
â 12.12
0
â
10
OUTPUT POWER
Vin = 16 to 40 VDC
0
â
40
0
â
50
OUTPUT RIPPLE
10 kHz - 2 MHz
LINE REGULATION
LOAD REGULATION
TC = 25°C
â
10
35
â
15
35
TC = -55°C TO +125°C
â
10
50
â
30
50
VIN = 16 TO 40 VDC
â
0
20
â
0
20
NO LOAD TO FULL
â
â
40
â
â
20
INPUT VOLTAGE
CONTINUOUS
16
28
40
16
28
40
TRANSIENT120 ms 1,2
â
â
50
â
â
50
INPUT CURRENT
NO LOAD
â
70
100
â
70
120
INHIBITED â INH1
â
9
14
â
9
14
INHIBITED â INH2
â
35
70
â
35
70
INPUT RIPPLE
10 kHz - 10 MHz
â
30
50
â
30
50
EFFICIENCY
LOAD FAULT
TC = 25°C
71
â
Ââ
TC = -55°C TO +125°C
69
â
â
SHORT CIRCUIT
POWER DISSIPATION
â
12.5
16
RECOVERY 1
1.5
6
75
78
â
73
â
â
â
12.5
18
1.5
4
STEP LOAD RESPONSE
50% - 100% - 50%
TRANSIENT
â ±200 ±300
â
±250 ±350
RECOVERY 1, 3
â
1.5
3.0
â
1.5
3.0
STEP LINE
RESPONSE 1, 3
16 - 40 -16 VDC
TRANSIENT 4
â ±250 ±300
â
±250 ±300
START-UP 5
Capacitive Load 6
RECOVERY
DELAY
TC = 25°C
â
200 300
â
â
3.5
10
â
â
â 1000
â
200 300
3.5
6
â 1000
Notes
1. Guaranteed by design, not tested.
2. Unit will shut down above approximately 45 V but will be undamaged and will
restart when voltage drops into normal range.
3. Recovery time is measured from application of the transient to point at
which VOUT is within 1% of final value.
4. Transition time 100 µs ±20%.
5. Tested on release from inhibit.
6. Shall not compromise DCâperformance.
UNITS
VDC
A
W
mV p-p
mV
mV
VDC
V
mA
mA p-p
%
W
ms
mV pk
ms
mV pk
µs
ms
µF
www.craneae.com/interpoint
Page 6 of 15
SMFL Rev K - 20101209
|
▷ |