English
Language : 

IA186EB Datasheet, PDF (80/85 Pages) InnovASIC, Inc – 8-Bit/16-Bit Microcontrollers
IA186EB/IA188EB
8-Bit/16-Bit Microcontrollers
Data Sheet
July 10, 2011
Errata No. 4
Problem: Timer 2 will stop or not start counting.
Description: Writing a logic ―1‖ to unused bits in the timer control register can cause the timer
to stop counting or to never start counting.
Workaround: Do not write a logic ―1‖ to any unused or reserved bits in the timer control
register.
Errata No. 5
Problem: Write does not occur when counter is actively counting.
Description: If a timer incremented its count register to the currently active compare register
during a write to that count register, the write would not occur.
Workaround: Do not write count register while that counter is actively counting.
Errata No. 6
Problem: Program Counter can become corrupted if an interrupt occurs.
Description: If an interrupt occurs during the decode stage of a TEST instruction using an
opcode of the form 1111_0111_1100_0xxx, the Program Counter could become corrupted upon
returning from the interrupt handler.
Workaround: None.
Errata No. 7
Problem: Bound instruction uses bad data when index addresses are on odd boundary in
memory.
Description: BOUND instruction will use bad data if index address LSB is a ―1‖ in memory.
Workaround: None.
IA211080314-13
UNCONTROLLED WHEN PRINTED OR COPIED
Page 80 of 85
http://www.Innovasic.com
Customer Support:
1-888-824-4184