English
Language : 

V23826-C18-C366 Datasheet, PDF (8/15 Pages) Infineon Technologies AG – DC/DC (3.3 V) Single Mode 155 MBd ATM/SDH/SONET 1x9 Transceiver Extended Temperature Range
V23826-C18-C366
Technical Data
Receiver Electro-Optical Characteristics
Parameter
Symbol
Limit Values
Unit
Sensitivity (Average Power)1)
Saturation (Average Power)
Signal Detect Assert Level2)
Signal Detect Deassert Level3)
Signal Detect Hysteresis
Signal Detect Assert Time
Signal Detect Deassert Time
Output Low Voltage4)
Output High Voltage4)
Output Data Rise/Fall Time,
20%–80%
PIN
PSAT
PSDA
PSDD
PSDA –
PSDD
tASS
tDAS
VOL - VCC
VOH - VCC
tR, tF
min.
–8
–44
1
–1950
–1025
typ.
–36
–37.5
–40
2.5
max.
–31
dBm
–34
6
dB
100
µs
350
–1620 mV
–720
375
ps
Output SD Rise/Fall Time
40
ns
1) Minimum average optical power at which the BER is less than 1x10-10 or lower. Measured with a 223 - 1 NRZ
PRBS as recommended by ANSI T1E1.2, SONET OC-3 and ITU-T G.957.
2) An increase in optical power of data signal above the specified level will cause the SIGNAL DETECT to switch
from a Low state to a High state.
3) A decrease in optical power of data signal below the specified level will cause the SIGNAL DETECT to switch
from a High state to a Low state.
4) DC/DC, PECL for Signal Detect, PECL compatible. Load is 50 Ω into VCC – 2 V for data, 500 Ω to VEE for Signal
Detect. Measured under DC conditions. For dynamic measurements a tolerance of 50 mV should be added.
VCC = 3.3 V. TAMB = 25°C.
Data Sheet
8
2000-04-01