English
Language : 

V23826-C18-C366 Datasheet, PDF (5/15 Pages) Infineon Technologies AG – DC/DC (3.3 V) Single Mode 155 MBd ATM/SDH/SONET 1x9 Transceiver Extended Temperature Range
Regulatory Compliance
Feature
Standard
Electrostatic Discharge MIL-STD 883C
(ESD) to the Electrical Method 3015.4
Pins
Immunity:
Electrostatic Discharge
(ESD) to the Duplex SC
Receptacle
EN 61000-4-2
IEC 61000-4-2
Immunity:
Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 61000-4-3
Emission:
Electromagnetic
Interference EMI
FCC Class B
EN 55022 Class B
CISPR 22
V23826-C18-C366
Description
Comments
Class 1 (>1000 V)
Discharges of ±15 kV with an air
discharge probe on the receptacle
cause no damage.
With a field strength of 10 V/m rms,
noise frequency ranges from
10 MHz to 1 GHz. No effect on
transceiver performance between
the specification limits.
Noise frequency range:
30 MHz to 6 GHz; Margins depend
on PCB layout and chassis design
Data Sheet
5
2000-04-01