2.3.3 Short circuit across the load
If short circuit messages from high- and low-side switch occur simultaneously within a
delay time of typically 2µs, the error bit “Short Circuit Over Load”, SCOL is set.
2.3.4 Over-Temperature
In case of high DC-currents, insufficient cooling or high ambient temperature, the chip
temperature may rise above the thermal shut-down temperature TSD. In that case, all
output transistors are shut-down and the error-bit “Over-Temperature”, OT is set.
2.3.5 Under-Voltage shut-down
If the supply-voltage at the VS pins falls below the under-voltage detection threshold, the
outputs are set to tristate and the error-bit “Under-Voltage at VS“ is set.