TLD1311EL_15 Datasheet, PDF (8/33 Pages) Infineon Technologies AG – 3 Channel High Side Current Source
TLD1311EL
General Product Characteristics
4
General Product Characteristics
4.1
Absolute Maximum Ratings
Absolute Maximum Ratings 1)
Tj = -40 °C to +150 °C; all voltages with respect to ground, positive current flowing into pin for input pins (I), positive
currents flowing out of the I/O and output pins (O) (unless otherwise specified)
Pos.
Parameter
Symbol
Limit Values Unit Conditions
Min.
Max.
Voltages
4.1.1 Supply voltage
4.1.2 Input voltage EN
4.1.3
4.1.4
4.1.5
Input voltage EN related to VS
Input voltage EN related to VOUTx
VEN - VOUTx
Output voltage
4.1.6
4.1.7
Power stage voltage
VPS = VS - VOUTx
Input voltage DIS
4.1.8 IN_SET voltage
4.1.9 N-1 voltage
4.1.10 Status voltage
Currents
VS
-16
40
V–
VEN
-16
40
V–
VEN(VS) VS - 40 VS + 16 V
–
VEN -
-16
40
VOUTx
V–
VOUTx
-1
40
V–
VPS
-16
40
V–
VDIS
-0.3
6
VIN_SET -0.3
6
VN-1
-0.3
6
VST
-0.3
6
V–
V–
V–
V–
4.1.11 IN_SET current
IIN_SET
–
2
mA –
–
8
Diagnosis output
4.1.12 N-1 current
4.1.13 Output current
Temperatures
IN-1
-0.5
0.5
mA –
IOUTx
–
130
mA –
4.1.14 Junction temperature
4.1.15 Storage temperature
ESD Susceptibility
Tj
-40
150
°C –
Tstg
-55
150
°C –
4.1.16 ESD resistivity to GND
VESD
-2
2
kV
4.1.17 ESD resistivity all pins to GND
VESD
-500
500
V
4.1.18 ESD resistivity corner pins to GND
VESD
-750
750
V
1) Not subject to production test, specified by design
2) ESD susceptibility, Human Body Model “HBM” according to ANSI/ESDA/JEDEC JS-001-2011
3) ESD susceptibility, Charged Device Model “CDM” according to JESD22-C101E
Human Body
Model (100 pF via
1.5 kΩ)2)
CDM3)
CDM3)
Note: Stresses above the ones listed here may cause permanent damage to the device. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Note: Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are
not designed for continuous repetitive operation.
Data Sheet
8
Rev. 1.1, 2015-03-19