TLD1311EL
Load Diagnosis
9
Load Diagnosis
9.1
N-1 Detection
The N-1 diagnosis is specially designed to detect error conditions in LED arrays with multiple LED chains used for
one light function. If one LED within one chain fails in open condition the respective LED chain is off. Different
automotive applications require a complete deactivation of a light function, if the desired brightness of the function
(LED array) can not be achieved due to an internal error condition. Such a deactivation feature is integrated in the
LITIXTM Basic IC.
The functionality of the N-1 pin is shown in the following block diagram:
N-1
IN-1
VN-1
Output Control
Figure 17 Block Diagram N-1 pin
In applications, where more than one LITIXTM Basic IC is used, the devices can be connected via the ST pins as
shown in Figure 21. This circuit can be used to disable all output stages (of all LITIXTM Basic ICs) during an open
load event on one channel. The outputs are deactivated after a N-1 filter time tN-1, which is defined by the charging
current IN-1 (Pos. 9.3.10). The time is adjustable with a capacitor connected to the N-1 pin according the following
equation:
ttyp
=
C-----N----–---1----⋅--V-----N----–---1--(--t--h--)
IN – 1
(3)