PEB3264FV1.4 Datasheet, PDF (79/374 Pages) Infineon Technologies AG – Dual Channel Subscriber Line Interface Concept
DuSLIC
Operational Description
Table 14 DuSLIC-S/-S2/-SE/-SE2 Operating Modes (cont’d)
SLICOFI-2S SLIC-S/S2
/SLICOFI-2S2 /SLIC-E/E2
Mode
Mode
Ringing (Ring) ACTR
Ring Pause ACTR
HIRT
HIRT
SLIC-S/-S2 System
Active
/SLICE/E2 Functionality Circuits
Internal
Supply
Voltages
(+/–) [VHI/VBI]
VHR/VBATH
Balanced ring Buffer,
signal feed Sensor, DC
(including DC loop, Ring
offset)
generator
VHR/VBATH
DC offset
feed
Buffer,
Sensor, DC
loop, Ramp
generator
VHR/VBATH
For example: Sensor, DC
sensor offset transmit
calibration path
Tip/Ring
Output
Voltage
Tip: (VBATH +
VHR + VDC)/2
Ring: (VBATH
+ VHR –
VDC)/2
Tip: (VBATH +
VHR + VDC)/2
Ring: (VBATH
+ VHR –
VDC)/2
High
Impedance
Active with HIR
HIR
VHR/VBATH
For example:
line test (Tip)
Tip Buffer,
Sensor,
DC + AC
loop
Tip: (VBATH +
VHR + VAC +
VDC)/2
Ring: High
impedance
Active with HIT
HIT
VHR/VBATH
For example: Ring Buffer, Ring: (VBATH
line test (Ring) Sensor, + VHR – VAC
DC + AC –VDC)/2
loop
Tip: High
impedance
1) Load external C for switching from PDRH to ACTH in on-hook mode.
VAC … Tip/Ring AC Voltage
VDC … Tip/Ring DC Voltage
Preliminary Data Sheet
79