Maximum Ratings and Operating Conditions
4
Maximum Ratings and Operating Conditions
4.1
Absolute Maximum Ratings
Absolute Maximum Ratings 1)
Tj = -40 ⋅C to +150 ⋅C; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Pos. Parameter
Symbol
Limit Values Unit Conditions
Min.
Max.
4.1.1 Supply Voltage
VDD
4.1.2 Continuous Drain Source Voltage
VDS
(OUT1 to OUT2)
-0.3
7
-0.3
48
V
–
V
–
4.1.3
4.1.4
4.1.5
Input Voltage, All Inputs and Data
outputs, Sense Lines
Output Current per Channel2)
Maximum Voltage for short circuit
Protection (single event)3)
VIN
-0.3
ID
-3
VSC, single –
7
V
ID(lim1,2) min. A
48
V
–
Output ON
Current Limit 2, slew
rate 1 (default setting)
–
32
V
Current Limit 2,
slew rate 2
–
18
V
Current Limit 1,
slew rate 1 or 2
4.1.6 Electrostatic Discharge Voltage
(human body model) according to
EIA/JESD22-A114-E
VESD
-4000
-2000
4000
2000
V
Output Pins
V
All other Pins
4.1.7 DIN Humidity Category, DIN 40 040
E
–
4.1.8 IEC Climatic Category, DIN IEC 68-1
40/150/ 56
–
1) Not subject to production test, specified by design.
2) Output current rating as long as maximum junction temperature is not exceeded. The maximum output current in the
application has to be calculated using RthJA depending onmounting conditions.
3) Device mounted on PCB (50 mm × 50 mm × 1.5 mm epoxy, FR4) with 6 cm2 copper heatsink area (one layer, 70 μm thick);
PCB in test chamber with blown air.
Note: Stresses above the ones listed here may cause permanent damage to the device. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Note: Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are
not designed for continuous repetitive operation.