English
Language : 

TLE5206-2G Datasheet, PDF (7/23 Pages) Infineon Technologies AG – 5-A H-Bridge for DC-Motor Applications
TLE 5206-2
Diagnosis
2
Diagnosis
Various errors as listed in the table “Diagnosis” are detected. Short circuits and overload
result in turning off the output stages after a delay tdSD and setting the error flag
simultaneously [EF = L]. Changing the inputs to a state where the fault is not detectable
resets the error flag (input toggling) with the exception of short circuit from OUT1 to
OUT2 (load short circuit).
Flag
Short circuit from OUT1 to OUT2
Short circuit from OUT1 to GND
Short circuit from OUT2 to GND
Short circuit from OUT1 to VS
Short circuit from OUT2 to VS
Overtemperature or undervoltage
IN1 IN2 OUT1 OUT2 EF Remarks
00L
L
1 Not detectable
01X
X
0
10X
X
0
11H
H
1 Not detectable
0 0 GND L
0 1 GND X
1 0 GND L
1 1 GND X
1 Not detectable
1 Not detectable
0
0
00L
01L
10X
11X
GND 1
GND 0
GND 1
GND 0
Not detectable
Not detectable
0 0 VS
X
0 1 VS
H
1 0 VS
X
1 1 VS
H
0
0
1 Not detectable
1 Not detectable
00X
01X
10H
11H
VS
0
VS
1 Not detectable
VS
0
VS
1 Not detectable
00Z
Z
0
01Z
Z
0
10Z
Z
0
11Z
Z
0
IN: 0 = Logic LOW
1 = Logic HIGH
OUT:
Z = Output in tristate condition
L = Output in sink condition
H = Output in source condition
X = Voltage level undefined
EF: 1 = No error
0 = Error
For Open circuit detection, use the TLE 5205-2.
Data Sheet
7
2001-06-19