1.7 Monitoring Functions
Undervoltage lockout (UVLO):
When VS reaches the switch on voltage VS ON the IC becomes active with a hysteresis.
All output transistors are switched off if the supply voltage VS drops below the switch off
value VS OFF.
1.8 Protective Function
Various errors like short-circuit to + VS, ground or across the load are detected. All faults
result in turn-OFF of the output stages after a delay of 50 µs and setting of the error flag
EF to ground. Changing the inputs resets the error flag.
a. Output Shorted to Ground Detection
If a high side transistor is switched on and its output is shorted to ground, the output
current is internally limited. After a delay of 50 µs all outputs will be switched-OFF and
the error flag is set.
b. Output Shorted to + VS Detection
If a low side transistor is switched on and its output is shorted to the supply voltage,
the output current is internally limited. After a delay of 50 µs all outputs will be
switched-OFF and the error flag is set.
c. Overload Detection
An internal circuit detects if the current through the low side transistor exceeds the
trippoint ISDL. In this case all outputs are turned off after 50 µs and the error flag is set.
d. Overtemperature Protection
At a junction temperature higher than 150 °C the thermal shutdown turns-OFF, all four
output stages commonly and the error flag is set with a delay.