English
Language : 

TC1782 Datasheet, PDF (57/130 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller
TC1782
Electrical ParametersGeneral Parameters
5.1.5 Operating Conditions
The following operating conditions must not be exceeded in order to ensure correct
operation and reliability of the TC1782.
Digital supply voltages applied to the TC1782 must be static regulated voltages which
allow a typical voltage swing of ± 5 %.
All parameters specified in the following tables refer to these operating conditions
(Table 18), unless otherwise noticed in the Note / Test Condition column.
The Voltage Operating Timing Profiles did not increase area of validity of the
parameters defined in table 8 and later.
Table 18 Operating Conditions Parameters
Parameter
Symbol
Values
Min. Typ. Max.
Overload coupling
KOVAN −
−
0.000
factor for analog inputs, CC
1
negative
Overload coupling
KOVAP −
−
0.000
factor for analog inputs, CC
01
positive
CPU Frequency
fCPU SR −
−
133
−
−
180
−
−
160
Unit Note /
Test Condition
IOV≤ 0 mA; IOV≥ -
2 mA; analog
pad= 5.0 V
IOV≤ 3 mA;
IOV≥ 0 mA; analog
pad= 5.0 V
MHz SAK-TC1782N-
256F133HR / SAK-
TC1782N-
256F133HL
MHz SAK-TC1782F-
320F180HR / SAK-
TC1782F-
320F180HL / SAK-
TC1782N-
320F180HR / SAK-
TC1782N-
320F180HL
MHz SAK-TC1782F-
320F160HR / SAK-
TC1782F-
320F160HL / SAK-
TC1782N-
320F160HR / SAK-
TC1782N-
320F160HL
Data Sheet
50
V 1.4.1, 2014-05