English
Language : 

TLE6244X Datasheet, PDF (50/70 Pages) Infineon Technologies AG – 18 Channel Smart Lowside Switch
TLE 6244X
A power stage that is switched off
in case of SCB can be switched on
again by an off/on cycle at the cor-
responding input pin resp. by the
change of the state of the corre-
sponding bit for SPI or µsec-bus
by a DEL_DIA instruction or can
be released again by reset. If the
fault register is cleared before this
release (by a DEL_DIA instruc-
tion), a new fault entry of SCB is
immediately carried out, even if
SCB condition is no longer
present.
For OUT9, OUT10
Above this limit short circuit to
UBatt is detected. The output cur-
rent is limited to approximately this
value if the static current limitation
is configured. An error is stored
after tDiag (see 3.11.4). If the oper-
ation leads to an overtemperature
condition, a second protection
level (about 170°C) will change the
output into a low duty cycle PWM
(selective thermal shutdown with
restart) to prevent critical chip tem-
peratures
Between -40°C and 150°C an
approximately linear characteristic
line can be assumed.
3.6.3.1 Maximum
Battery Volt-
age at Short
Circuit to Bat-
tery
See Note 1.11.1
C UOUT 36
V
9..14
3.6.4 Shutoff Delay Shutoff delay of the power stages
B
after detection of KSUB. For the
duration of tVoff current is limited to
maximum current.
tVoff
60
215 µs
3.6.5 On Resis-
tance
TJ = 25°C
TJ = 150°C
TJ = -40°C
For UUBatt ≤ 10V Ron is increased
up to 20%.
A Ron9-14 200 300 380 mΩ
A Ron9-14 380 550 680 mΩ
A Ron9-14 150 220 280 mΩ
Final Data Sheet
50
V4.2, 2003-08-29