English
Language : 

V23836-C18-C63 Datasheet, PDF (5/13 Pages) Infineon Technologies AG – 1x9 Transceiver with Duplex SC Receptacle Single Mode 1300 nm 21 km SONET OC-3 / SDH STM-1
V23836-C18-C63
V23836-C18-C363
Description
Regulatory Compliance
Feature
Standard
ESD:
MIL-STD 883D
Electrostatic Discharge Method 3015.7
to the Electrical Pins JESD22-A114-B
Immunity:
Electrostatic Discharge
(ESD) to the Duplex SC
Receptacle
EN 61000-4-2
IEC 61000-4-2
Immunity:
Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 61000-4-3
Emission:
Electromagnetic
Interference (EMI)
FCC 47 CFR Part 15
Class B
EN 55022 Class B
CISPR 22
Comments
Class 1 (> 1000 V) HBM
Class 1C
Discharges of ±15 kV with an air
discharge probe on the receptacle
cause no damage.
With a field strength of 3 V/m, noise
frequency ranges from 10 MHz to
2 GHz. No effect on transceiver
performance between the
specification limits.
Noise frequency range:
30 MHz to 18 GHz;
Margins depend on PCB layout and
chassis design.
Preliminary Product Information
5
2004-02-13