Preliminary Datasheet TLE 6214 L
Output Tri-state Leakage Current
FAULT Output Low Voltage
Status Output Low Voltage
CS = H, 0 ≤ VSO ≤ VS
IFAULT = 1.6 mA
IST = 1.6 mA
5. SPI
Serial Clock Frequency (depending on SO load)
Serial Clock Period (1/fsclk)
Serial Clock High Time
Serial Clock Low Time
Enable Lead Time (falling edge of CS to rising edge of
SCLK)
Enable Lag Time (falling edge of SCLK to rising edge of
CS)
Data Setup Time (required time SI to falling of SCLK)
Data Hold Time (falling edge of SCLK to SI)
Disable Time
Transfer Delay Time1
(CS high time between two accesses)
Data Valid Time
CL = 50 pF
CL = 100 pF
6. Diagnostic Functions
Open Load Detection Voltage(Channel OFF)
ISOlkg
VFAULTL
VST
fSCK
tp(SCK)
tSCKH
tSCKL
tlead
tlag
tSU
tH
tDIS
tdt
tvalid
VDS(OL)
Output Pull Down Current
Fault Filtering Time
Overload switch off delay time (only current limit 2)
Short to Ground Detection Voltage
IPD(OL)
td(fault)
Td(off)
VDS(SHG)
Short to Ground Detection Current(Channel OFF)
Under Current Detection Threshold (Channel ON)
Current Limit1; Overload Threshold Current1
Current Limit2; Overload Threshold Current2
IC Overtemperature Warning
Hysteresis
Channel Overtemperature Shutdown
Hysteresis
5. Analog Current Sense Output (IS1 / IS2)
Current Sense Precision (single channel)2 I FB / I OUT
ID = 200mA – 1A; UCO1 ≥ 2V
ISHG
ID(OL)
ID(lim1)
ID(lim2)
Tw
T(w) hys
Tth(sd)
T(sd)hys
PIS
-10 0
10
µA
--
--
0.4
V
0.4
V
DC --
200 --
80 --
80 --
200 --
200 ---
20 --
20 --
--
--
300 --
--
--
--
--
5
MHz
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
150 ns
--
ns
120 ns
150
--
0.6* --
V
Vs
25 50
100
µA
50 100 200
µs
10
50
µs
--
0.4* --
V
Vs
-50 -100 -150 µA
100 170 300 mA
5
6.5 8
A
9
10,5 12
A
155 --
185
°C
-- 10
--
K
170 --
200
°C
--
10 --
K
0.8 1.0 1.2
mA
/A
1 This time is necessary between two write accesses. To get the correct diagnostic information, the transfer delay
time has to be extended to the maximum fault delay time td(fault)max = 200µs.
2 If the summed current is sensed the tolerances of the single channels are added.
V2 Preliminary
Page 4