English
Language : 

TLE6214L Datasheet, PDF (11/17 Pages) Infineon Technologies AG – Smart Dual Current Sense Switch
Preliminary Datasheet TLE 6214 L
Diagnostic Table
In general the status follows the input signal in normal operating conditions.
If any error is detected the status is inverted.
Operating Condition
Con- Power
trol Output
Input
Sleep Mode
X
Normal function
L
H
Short to ground1)
“off” L
H
Open load1)
Under current1)
“off” L
“on” H
Overload or short to supply1) H
(Current limit 1 / Limitation)
Overload or short to supply2) H
(Current limit 2 / Shutoff)
Overtemperature
H
(Restart mode)
Overtemperature
H
(Latch mode)
off
off
on
off
on
off
on
on
off
off 3)
off 4)
Filter
time
td(fault)
td(fault)
td(fault)
td(fault)
td(fault)
td(off)
no
no
Status FAULT SPI diagnostic
Output Output
feedback
Channel Channel
Diagnostic overtemp
bits
. flag
MSB LSB
L
H- - -
L
H HH L
H
H HH L
H
L LL L
L
L LH L
H
L LH L
L
L LH L
L
L HL L
L
L HL L
L
L HL H
L
L HL H
Note 1) Short to ground/open load/ under current /overload/short-to-supply - events shorter than min.
time td(fault) will not be latched and not reported at the diagnosis pins.
Note 2) Overload/short-to-supply - events shorter than min. time td(off) will not be latched and not
reported at the diagnosis pins.
Note 3) Off as long as overtemperature occurs, restart after cooling down.
Note 4) Shutdown latch reset by falling input edge
V2 Preliminary
Page 11
25.06.2003