ICE3RBR0665JG Datasheet, PDF (30/32 Pages) Infineon Technologies AG – Fixed-Frequency, 650V CoolSET™ in DS0-12 Package
Fixed-Frequency, 650V CoolSET™ in DS0-12 Package
Schematic for recommended PCB layout
9
Schematic for recommended PCB layout
Figure 36 Schematic for recommended PCB layout
General guideline for PCB layout design using F3 CoolSET™ (Figure 36):
1. “Star Ground “at bulk capacitor ground, C11:
“Star Ground “means all primary DC grounds should be connected to the ground of bulk capacitor C11
separately in one point. It can reduce the switching noise going into the sensitive pins of the CoolSET™
device effectively. The primary DC grounds include the followings.
a. DC ground of the primary auxiliary winding in power transformer, TR1, and ground of C16 and Z11.
b. DC ground of the current sense resistor, R12
c. DC ground of the CoolSET™ device, GND pin of IC11; the signal grounds from C13, C14, C15 and collector of
IC12 should be connected to the GND pin of IC11 and then “star “connect to the bulk capacitor ground.
d. DC ground from bridge rectifier, BR1
e. DC ground from the bridging Y-capacitor, C4
2. High voltage traces clearance:
High voltage traces should keep enough spacing to the nearby traces. Otherwise, arcing would incur.
a. 400 V traces (positive rail of bulk capacitor C11) to nearby trace: > 2.0 mm
b. 600 V traces (drain voltage of CoolSET™ IC11) to nearby trace: > 2.5 mm
3. Filter capacitor close to the controller ground:
Filter capacitors, C13, C14 and C15 should be placed as close to the controller ground and the controller
pin as possible so as to reduce the switching noise coupled into the controller.
Guideline for PCB layout design when > 3 kV lightning surge test applied (Figure 36)
1. Add spark gap
Spark gap is a pair of saw-tooth like copper plate facing each other which can discharge the accumulated
charge during surge test through the sharp point of the saw-tooth plate.