English
Language : 

TLE7237GS Datasheet, PDF (29/36 Pages) Infineon Technologies AG – 8 Channel High-Side and Low-Side Relay Switch
TLE7237GS
Serial Peripheral Interface (SPI)
Field
TER
RB
ADDR
DATA
Bits
Type Description
Transmission Error
0 Previous transmission was successful (modulo 8 clocks
received)
1 Previous transmission failed or first transmission after reset
0
Register Bank
0 CONTR Control Register Bank
1 DIAG Diagnosis Register Bank (read only)
6:4
Address
Pointer to register for read and write command
3:0
Data
Data written to or read from register selected by address ADDR
Standard Diagnosis:
Field
Bits
AWK
5
Dxy
3, 2, 1, 0
Type
Description
Awake, Device active
Failure mode alert of channel x and y
9.4
Register Overview
Control Register Bank
Name
Addr
3
2
1
0
ICR01
000B
INX1
INX0
ICR23
001B
INX3
INX2
ICR45
010B
INX5
INX4
ICR67
011B
INX7
INX6
DCCR0
100B
DCEN3
DCEN2
DCEN1
DCEN0
DCCR1
CMD
101B
110B
DCEN7
WAKE
DCEN6
STB
DCEN5
RST
DCEN4
CPL2)
unused
111B
–
–
–
–
1) The default values are set after Vbb power-on, STB-command and RST-command
All command bits are cleared at the end of transmission, respectively after execution
2) CPL bit needs a valid next SPI communication frame to be cleared
default1)
0H
0H
0H
0H
0H
0H
0H
0H
type
r/w
r/w
r/w
r/w
r/w
r/w
w
–
Data Sheet
29