TLE5011
Specification
Abbreviation
S
R
W
Function
Status
Read
Write
Description
Reset only after readout
Read-only registers
Read and write registers
CTRL1
Addr: 00H
Reset Value: 01H
7
6
5
4
3
2
1
0
reserved
reserved
reserved
reserved SSC_FILT reserved
AUTO
UR
-
-
-
WL
WL
-
WL
WL
Field
reserved
reserved
reserved
reserved
SSC_FILT
reserved
AUTO
UR
Bits
Type
Description
7
-
Reserved, must be set to 0
6
-
Reserved, must be set to 0
5
-
Reserved, must be set to 0
4
-
Reserved, must be set to 0
3
WL
SSC Digital Spike Filter enable for all SSC lines ( CS, CLK and
DATA )
0: Digital SSC Spike filters off
1: Digital SSC Spike filters on (modified timing)
2
-
Reserved, must be set to 0
1
WL
Automatic update at angle tests
0: no automatic update in Angle Test Mode
1: automatic update-command after tsettle,
counters FSYNC and FCNT are reset to 0. Then the Angle-Test
(ANGT_EN) is automatically disabled and switches back to normal
operation.
Also, the UPDATE bit is toggled
0
WL
Update / Run Mode
0: Run Mode (Buffer1 values are immediate values)
1: Update Mode (Buffer2 values are stored values)
The values in Register 01H to 04H represent one Byte of two’s complement signed 16 bit integer values.
X_L
Addr: 01H
Reset Value: 00H
7
6
5
4
3
2
1
0
X Low Byte
RU
X_H
Addr: 02H
Reset Value: 00H
7
6
5
4
3
2
1
0
X High Byte
RU
Final Data Sheet
27