English
Language : 

TLE5011 Datasheet, PDF (23/43 Pages) Infineon Technologies AG – GMR Angle Sensor
TLE5011
Specification
DATA Write Time ( tDATW )
During this time, the TLE5011 changes the data line, so the data are invalid. The DATA Write Time values are
defined without a pull-up resistor.
Pull-up Time Value ( tPU )
The value in Table 11 “SSC Timing Specification” on Page 23 is estimated at 60 ns.
Table 11 SSC Timing Specification
Note: Timing must be calculated according to Table 10 “CLK Timing Specification” on Page 21
Parameter
Symbol Limit Values
Unit
Notes
min.
typ. max.
SSC Baud Rate
fSSC
-
2.0 2.11)
Mbit / s
CS Setup Time
tCSs
3*tDIG+10
-
-
ns
CS Hold Time
tCSh
5*tDIG+10
-
-
ns
CSoff
tCSoff
10*tDIG
-
-
ns
SCK High
tSCKh
5*tDIG
-
-
ns
SCK Low
tSCKl
5*tDIG
-
-
ns
DATA Read Time
tDATr
(Data Valid Time)
6*tDIG-10
-
5*tDIG-10
-
7*tDIG+10
ns
7*tDIG+10
DATA Write Time
(Data Valid Time) 2)
tDATw
6*tDIG+25
-
7*tDIG+50 + tPU ns
DATA slope
tDATs
-
20
30 3)
ns
1) fCLK/2, synchronized to fCLK if fCLK = fCLK(max)
2) tPU is the time generated by the pull-up resistor
3) Not tested
4) Internal slope control of falling edge for data bit transition from VH to VL.
SSC inactive time
SSC_FILT = 0
SSC_FILT = 1
Falling edge 4)
SCK
S S C_FIL T=0
tSCKl MIN
tDATw MIN
tDATw MAX
tSCKh
Wr tPU
tDATr MIN
tDATr MAX
Earliest sample timepoint
Rd
SCK
S S C_ FIL T=1
tDATw MIN
tDATw MAX
Wr tPU
tDATr MIN
tDATr MAX
Earliest sample timepoint of
second sample from 2 of 3 filter
Rd
Figure 12 SSC Interface Timing Details - Worst-Case Specified Timing
Note: The read window includes the sampling of the data bit. For SSC_FILT = 1, the 2-of-3 selection is already
considered. Only the two last data values need to be equal. For SSC_FILT = 0, only one sample point is
selected.
Final Data Sheet
23
V1.1, 2010-05