ICB1FL03G Datasheet, PDF (25/38 Pages) Infineon Technologies AG – Smart Ballast Control IC for Fluorescent Lamp Ballasts
ICB1FL03G
Electrical Characteristics
6.3.3
Inverter Section
6.3.3.1 Inverter Control (RFRUN, RFPH, RTPH)
Parameter
Fixed Start-Up Frequency
Duration of Soft Start, shift F from
Start-Up to Preheating Frequency
Preheating Frequency
Symbol
Fstartup
tsoftstart
FRFPH1
min.
112
9.0
Limit Values
typ.
max.
125
138
11.0 13.5
97.0 100
103.0
Unit
kHz
ms
kHz
Run Frequency
Preheating Time
Preheating Time
Current Source Preheating Time
Min. Duration of Ignition, shift F from
Preheating to Run Frequency
FRFRUN1
tRTPH1
tRTPH2
IRTPH
tIGNITION
Max. Duration of Ignition, shift F from tNOIGNITION
Preheating to Run Frequency
Duration of Pre-Run, time period after tPRERUN
operating frequency has reached Run
Frequency first time after ignition
Minimum Duration of fault condition
by EOL2, Cap.Load 1, Open filament
and Overvoltage for entering latched
Fault Mode
tCAPLOAD1
Minimum Duration of fault condition
by EOL1, Cap.Load 2 for entering
latched Fault Mode
tCAPLOAD2
49.0
720
50
132
34
210
210
420
520
50.0
900
90
140
40
235
250
500
610
51.0 kHz
1080 ms
130
ms
148
µA
48
ms
290
ms
290
ms
580
ms
770
µs
1) The parameter is not subject to production test - verified by design/characterization
Test Condition
RRFPH = 10kΩ
RRFRUN = 10kΩ
RRFRUN = 10kΩ
RRTPH = 8.06kΩ
RRTPH = 806Ω1)
1)
1)
1)
1)
6.3.3.2 Inverter Low Side Current Sense (LSCS)
Parameter
Symbol
Current Limit Threshold during
Ignition Mode
Duration of Current above Threshold
for enabling Frequency Increase
Overcurrent Shut Down Threshold
Duration of Overcurrent for entering
Latched Fault Mode
Bias Current LSCS
Inverter Dead Time between LS off
and HS on
VLSCSlimit
tLSCSlimit
VLSCSovc
tLSCSovc
ILSCSbias
tdeadtime
min.
0.76
Limit Values
typ.
max.
0.80 0.84
200
250
320
1.55 1.60 1.65
320
400
480
-0.5
0.5
1.50 1.75 2.0
Unit
V
ns
V
ns
µA
µs
Test Condition
VLSCS = 1.5V
Preliminary Datasheet Version 1.02
25
March 2009