ICB1FL03G Datasheet, PDF (14/38 Pages) Infineon Technologies AG – Smart Ballast Control IC for Fluorescent Lamp Ballasts
ICB1FL03G
Functional Description
3.4 Detection of End-of-Life and Rectifier Effect
After ignition the lamp voltage breaks down to its run voltage level (typically 50Vpeak to 300Vpeak). Reaching the
run frequency there follows a time period of 250ms called Pre-Run Mode, in which some of the monitoring features
(EOL1, EOL2, Cap.Load1) are still disabled. In the subsequent Run Mode the End-of-life (EOL) monitoring is
enabled. The event EOL1 is detected by measuring the positive and negative peak level of the lamp voltage by a
current fed into the LVS pin (R41, R42, R43 in Fig. 11). If the sensed current exceeds 215µA for longer than 610µs
the status end-of-life (EOL1) or the exceeding of the maximum output power is detected. In Fig. 12 the different
levels of the sensed lamp voltage are illustrated.