English
Language : 

TLE4675 Datasheet, PDF (20/25 Pages) Infineon Technologies AG – Low Drop Out Linear Voltage Regulator 5V Fixed Output Voltage
TLE4675
Reset Function
7.2
Electrical Characteristics Reset Function
Electrical Characteristics: Reset Function
VI = 13.5 V, Tj = -40 °C to +150 °C,
all voltages with respect to ground, direction of currents as shown in Figure 7 (unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
Output Undervoltage Reset Comparator Default Values
7.2.1
Output Undervoltage
Reset Lower Switching
Threshold
VRT,lo
4.6 4.7 4.8 V
VI = 0 V
VQ decreasing
7.2.2
Output Undervoltage
Reset Upper Switching
Threshold
VRT,hi
4.7 4.8 4.9 V
VI within operating range
VQ increasing
7.2.3
Output Undervoltage
Reset Switching
Hysteresis
VRT,hy
50 100 –
mV VI within operating range
7.2.4 Output Undervoltage
VRH
Reset Headroom
Reset Output RO
250 300 –
mV Calculated Value:
VQ - VRT,lo
VI within operating range
IQ = 50 mA
7.2.5 Reset Output Low Voltage VRO,low
7.2.6
Reset Output
Sink Current Capability
IRO,max
7.2.7
7.2.8
Reset Output
External Pull-up Resistor
to VQ
Reset Output
Leakage Current
RRO
IRO,leak
–
0.2 0.8 V
VI = 0V
1 V ≤ VQ < VRT,low;
IRO = 0.3 mA
0.3 –
–
mA VI = 0V;
1 V ≤ VQ < VRT,low;
VRO = 5V
3.0 –
–
kΩ 1 V ≤ VQ < VRT;
VRO ≤ 0.4V 1)
–
5
10
µA VRO = 5 V
Reset Delay Timing
7.2.9
7.2.10
Delay Pin Output Voltage
Upper Delay
Switching Threshold
VD
VDST,hi
–
–
5
–
1.1 –
V
–
V
–
7.2.11 Lower Delay
Switching Threshold
VDST,lo
–
0.3 –
V
–
7.2.12 Delay Capacitor
Charge Current
ID,ch
–
3.5 –
µA VD = 1 V
7.2.13 Delay Capacitor
IDR,dsch
Reset Discharge Current
–
70
–
mA VD = 1 V
7.2.14 Undervoltage Reset Delay td,100nF
Time
16
23
30
ms Calculated value;
CD = 100 nF2)
CD discharged to VDST,lo
Data Sheet
20
Rev. 1.0, 2008-09-30