Reset Function
Reset Reaction Time
In case the output voltage of the regulator drops below the output undervoltage lower reset threshold VRT,lo, the
delay capacitor CD is discharged rapidly. Once the delay capacitor’s voltage has reached the lower delay
switching threshold VDST,lo, the reset output RO will be set to “low”.
Additionally to the delay capacitor discharge time trr,d an internal time trr,int applies. Hence the total reset reaction
time trr,total becomes:
trr,total = trr,int + trr,d
with
• trr,total: total reset reaction time
• trr,int: Internal reset reaction time; see Item 7.2.16
• trr,d: Delay capacitor discharge time. For a capacitor CD different from the value specified in Item 7.2.17, see
typical performance graphs.
Reset Output Pull-Up Resistor RRO:
The Reset Output RO is an open collector output requiring an external pull-up resistor to a voltage VIO, e.g. VQ. In
Item 7.2.7 a minimum value for the external resistor RRO is given for the case it is connected to VQ.
For applications, where the external pull-up resistor RRO has to be connected to a different voltage rail VIO than
VQ, the minimum pull-up resistor RRO can be calculated out of the minimum sink current capability given in
Item 7.2.6:
:
RRO = V-----I--O-I--R-–--O---V-,--m-R---aO--x--,-l-o--w--
with
• RRO: Reset pull up resistor
• VIO: Voltage rail, where the pull up resistor is connected
• VRO,low: Maximum allowed voltage level for a logic “Low” signal inside the application
Please be aware, that VIO should not exceed the ratings for the RO pin given in Item 4.1.3.
Reset Output “RO” Low for VQ ≥ 1 V
In case of an undervoltage reset condition reset output “RO” is held “low” for VQ ≥ 1 V, even if the input voltage VI
is 0 V. This is achieved by supplying the reset circuit from the output capacitor.
Data Sheet
17
Rev. 1.0, 2008-09-30