English
Language : 

TLE7368 Datasheet, PDF (19/39 Pages) Infineon Technologies AG – Next Generation Micro Controller Supply
TLE7368
General Product Characteristics
Electrical Characteristics (cont’d)
VIN = VIN_STBY = 13.5 V, Tj = -40 °C to +150 °C,
VCCP = 9.0 V; SEL_STBY = Q_STBY; all voltages with respect to ground.
Pos. Parameter
Symbol
Limit Values
Unit
Conditions
Min. Typ. Max.
4.4.98 Overvoltage Reset
VORT Q_LDO2, 2.85 –
threshold on Q_LDO2 in
4.4.99 Overvoltage Reset
VORT Q_LDO2, 2.73 –
threshold on Q_LDO2 de
4.4.100 Overvoltage Reset
VORO_2, hyst 50
–
hysteresis Q_LDO2
3.0 V SEL_LDO2 = GND;
VQ_LDO2 increasing
2.95 V SEL_LDO2 = GND;
VQ_LDO2 decreasing
120 mV SEL_LDO2 = GND;
4.4.101 Undervoltage Reset
VURT FB_EXT, 1.425 –
threshold on FB_EXT de
4.4.102 Undervoltage Reset VFB_EXT - 40
60
headroom on FB_EXT VURT FB_EXT,
de
4.4.103 Undervoltage Reset
VURO_2, hyst 15
–
hysteresis FB_EXT
1.480 V
–
mV
45 mV
VFB_EXT decreasing;
VFB/L_IN = 5 V
or VQ_LDO2 = 3.3/2.6 V
VFB/L_IN = 5 V
or VQ_LDO2 = 3.3/2.6 V;
VFB_EXT @ IFB_EXT = 1 A
–
4.4.104 Overvoltage Reset
VORT FB_EXT, 1.65 –
threshold on FB_EXT in
4.4.105 Overvoltage Reset
VORT FB_EXT, 1.55 –
threshold on FB_EXT de
4.4.106 Overvoltage Reset
VORO_2, hyst 50
–
hysteresis FB_EXT
1.72 V
VFB_EXT increasing
1.67 V
VFB_EXT decreasing
120 mV –
4.4.107 RO_2, Reset output low VRO_2, low
–
–
voltage
4.4.108 RO_2, Reset output low VRO_2, low
–
–
voltage
4.4.109 RO_2, Reset output
IRO_2, high
-1
–
leakage
0.4 V
IRO_2 = -10 mA;
VQ_LDO2 > 2.0 V
0.25 V
IRO_2 = -500 µA;
VQ_LDO2 = 1V
1
µA VRO_2 = 5.0 V
4.4.110 Reset delay time RO_2 tRD, RO_2
–
4.4.111 Undervoltage Reset
reaction time
tUVRR, RO_2
2
4.4.112 Undervoltage Reset
reaction time
tUVRR, RO_2
2
4.4.113 Overvoltage Reset
reaction time
tOVRR, RO_2 20
4.4.114 Overvoltage Reset
reaction time
tOVRR, RO_2 20
160 –
–
10
–
10
–
80
–
80
Tcycle
µs
µs
µs
µs
–
Voltage step on Q_LDO2 from
VQ_LDO2, nom to
VURT Q_LDO2, de, min - 20 mV
Voltage step on FB_EXT from
VFB_EXT, nom to
VURT FB_EXT, de, min - 20 mV
Buck converter operating;
Voltage step on Q_LDO2 from
VQ_LDO2, nom to
VORT Q_LDO2, in, max + 20 mV
Buck converter operating;
Voltage step on FB_EXT from
VFB_EXT, nom to
VORT FB_EXT, in, max + 20 mV
Data Sheet
19
Rev. 1.1, 2007-11-08