English
Language : 

TLE42754_08 Datasheet, PDF (19/26 Pages) Infineon Technologies AG – Low Dropout Linear Fixed Voltage Regulator
TLE42754
Block Description and Electrical Characteristics
Electrical Characteristics Reset Function
VI = 13.5 V, -40 °C ≤ Tj ≤ 150 °C, all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
Output Undervoltage Reset
5.3.1 Output Undervoltage Reset
Switching Thresholds
VRT
4.5
4.65 4.8
V
VQ decreasing
Reset Output RO
5.3.2 Reset Output Low Voltage
5.3.3
5.3.4
Reset Output
Sink Current Capability
Reset Output
Leakage Current
VRO,low
–
0.2
0.4
V
1 V ≤ VQ ≤ VRT ;
IRO = 0.2 mA
IRO,max
0.2
–
–
mA 1 V ≤ VQ ≤ VRT ;
VRO = 5 V
IRO,leak
–
0
10
µA
VRO = 5 V
5.3.5 Reset Output External
Pull-up Resistor to VQ
Reset Delay Timing
RRO
5
–
–
kΩ
1 V ≤ VQ ≤ VRT ;
VRO ≤ 0.4 V
5.3.6
5.3.7
Power On Reset Delay Time
Upper Delay
Switching Threshold
trd
10
16
22
ms CD = 47 nF
VDU
–
1.8
–
V
–
5.3.8 Lower Delay
Switching Threshold
VDRL
–
0.65 –
V
–
5.3.9 Delay Capacitor
Charge Current
ID,ch
–
5.5
–
µA VD = 1 V
5.3.10 Delay Capacitor
Reset Discharge Current
ID,dch
–
100 –
mA VD = 1 V
5.3.11 Delay Capacitor
Discharge Time
trr,d
–
5.3.12 Internal Reset Reaction Time
trr,int
–
0.5
1
4
7
µs Calculated Value:
trr,d = CD*(VDU -
VDRL)/ ID,dch
CD = 47 nF
TLE42754D
TLE42754G
µs
CD = 0 nF1)
TLE42754D
TLE42754G
5.3.13 Reset Reaction Time
trr,total
–
4.5
8
µs Calculated Value:
trr,total = trr,int + trr,d
CD = 47 nF
TLE42754D
TLE42754G
1) parameter not subject to production test; specified by design
Data Sheet
19
Rev. 1.1, 2008-09-24