CoolSET™-F3
ICE3xxx65L
Functional Description
blocks C12 by the gate G10. Maximum current can now
be provided to stabilize VOUT.
VFB
4.80V
4.00V
3.40V
Entering Active Leaving Active
Burst Mode
Burst Mode
1.30V
VSoftS
t
Blanking Window
5.40V
4.40V
VCS
t
3.6.3
Protection Modes
The IC provides several protection features which are
separated into two categories. Some enter Latched Off
Mode, the others enter Auto Restart Mode. The
Latched Off Mode can only be reset if VCC is falling
below 6V. Both modes prevent the SMPS from
destructive states. The following table shows the
relationship between possible system failures and the
chosen protection modes.
VCC Overvoltage
Latched Off Mode
Overtemperature
Latched Off Mode
Short Winding/Short Diode Latched Off Mode
Overload
Auto Restart Mode
Open Loop
Auto Restart Mode
VCC Undervoltage
Auto Restart Mode
Short Optocoupler
Auto Restart Mode
Current limit level during
1.00V Active Burst Mode
3.6.3.1 Latched Off Mode
CS
0.257V
VVCC
Latched Off
Mode Reset
t
VVCC < 6V
Spike
1
C11 Blanking
1.70V
190ns
G3
Latched
Off Mode
8.5V
IVCC
7.2mA
VCC
t
C1
28V
Spike
Blanking
8.0us
1.05mA
VOUT
t
Max. Ripple < 1%
Thermal Shutdown
Tj >140°C
Voltage
Reference
Control Unit
Figure 16 Signals in Active Burst Mode
Version 2.0
Figure 17 Latched Off Mode
t The VCC voltage is observed by comparator C1 if 21V
is exceeded. The output of C1 is combined with the
output of C4 which observes FB signal if 4.8V is
13
8 May 2006