English
Language : 

ICE2PCS04 Datasheet, PDF (13/19 Pages) Infineon Technologies AG – Standalone PFC Controller in CCM with Input Brown-Out Protection
4 Electrical Characteristics
CCM-PFC
ICE2PCS04/G
Electrical Characteristics
4.1 Absolute Maximum Ratings
Note: Absolute maximum ratings are defined as ratings, which when being exceeded may lead to destruction
of the integrated circuit.
Parameter
Symbol
Limit Values Unit Remarks
min. max.
VCC Supply Voltage
VINS Voltage
VINS Current
ICOMP Voltage
ISENSE Voltage
ISENSE Current
VSENSE Voltage
VSENSE Current
VCOMP Voltage
GATE Voltage
VCC
VVINS
IINS
VICOMP
VISENSE
IISENSE
VVSENSE
IVSENSE
VVCOMP
VGATE
-0.3
25
-0.3
9.5
-1
35
-0.3
5
-20
5
-1
1
-0.3
5
-1
1
-0.3
5
-0.3
17
V
V
3)
uA
V
V
2)
mA
Recommended R2=220Ω
V
mA
R3>400kΩ
V
V
Clamped at 15V(typ)
if driven internally.
Junction Temperature
Storage Temperature
Thermal Resistance
Junction-Ambient for PG-DSO-8
Tj
-40
TS
-55
RthJA (DSO) -
150
°C
150
°C
185
K/W PG-DSO-8
Thermal Resistance
Junction-Ambient for PG-DIP-8
ESD Protection
RthJA(DIP) -
VESD
-
90
K/W PG-DIP-8
2
kV
Human Body Model1)
1) According to EIA/JESD22-A114-B (discharging a 100pF capacitor through a 1.5kΩ series resistor)
2) Absolute ISENSE current should not be exceeded
3) Absolute VINS current should not be exceeded
4.2 Operating Range
Note: Within the operating range the IC operates as described in the functional description.
Parameter
VCC Supply Voltage
Junction Temperature
Symbol
VCC
TJCon
Limit Values
min. max.
VCCUVLO 25
-40
125
Unit
V
°C
Remarks
Version 2.0
13