English
Language : 

TLE6232GP Datasheet, PDF (12/19 Pages) Infineon Technologies AG – Smart Six Channel Low-Side Switch
Data Sheet TLE 6232 GP
- Read back of SCON_REG (SCON bits 6 to 1 and two high bits)
- Read back of MUX_REG (MUX information for channel 6 to 1 and two high bits)
- Diagnostic information of channel 4 to 1 (2 bits per channel)
On a writing access always the full diagnostic information of the 6 channels (2 bit per channel)
and the over-temperature and common fault bit is performed.
Invalid instruction/access:
An instruction is invalid, if the following condition is fulfilled:
- an unused instruction code is detected (see tables with SPI instructions).
If an invalid instruction is detected, a writing access on a register of TLE6232 GP is not allow-
wed. In addition an access is invalid if the number of SPI clock pulses counted during active
CS differs from exactly 16 clock pulses (falling edges are counted).
- On a writing access the received data is only taken over into the internal registers and
- the fault register is only cleared by the RD_DIAG command,
if exactly 16 SPI clock pulses were counted while CS active.
Writing access / 8 bit + 8 bit resp.
SS
SPI Instruction
SI
1 0 - - -- - -
Data/8 Bit
MSB
MSB
SO
Z Z F OT DIA6 DIA5
DIA4 DIA3 DIA2 DIA1
MSB
Reading access / 8 bit + 8 bit
SS
SPI Instruction
SI
1 0- - - - --
XXXX XXXX
MSB
SO
Z Z F OT DIA6 DIA5
Data/8 Bit
MSB
MSB
V1.2
Page 12
08.Oct. 2003