English
Language : 

HDSP2110S Datasheet, PDF (10/13 Pages) Infineon Technologies AG – 8-Character 5x7 Dot Matrix Parallel Input Alphanumeric Intelligent Display
Blink Function
Control Word bit, D4, enables or disables the Blink Function.
When D4 is 1, the Blink Function is enabled and all characters
on the display will blink at approximately 2.0 Hz. The Blink
Function will override the Flash Function if both functions are
enabled. When D4 is 0, the Blink Function is disabled. When
using an external clock, the blink rate can be determined by
dividing the clock rate by 28,672. For synchronized blinking on
multiple displays, see the Reset Section.
Self Test
Before starting Self Test, Reset must first be activated. Control
Word bits, D6 and D5, are used for the Self Test Function.
When D6 is 1, the Self Test is initiated. Results of the Self Test
are stored in bits D5. Control Word bit, D5, is a read only bit.
When D5 is 1, Self Test passed is indicated. When D5 is 0, Self
Test failed is indicated. The Self Test function of the IC consists
of two internal routines which exercise major portions of the IC
and illuminates all of the LEDs. The first routine cycles the
ASCII decoder ROM through all states and performs a check
sum on the output. If the check sum agrees with the correct
value, D5 is set to a 1.
Figure 10. UDC Character Map
Row Data
Column Data
C1 C2 C3 C4 C5
A2 A1 A0 Row # D4 D3 D2 D1 D0
0 0 01
0 0 12
0 1 03
0 1 14
1 0 05
5x7
Dot Matrix
Pattern
1 0 16
1 1 07
The second routine provides a visual test of the LEDs using the
drive circuitry. This is accomplished by writing checkered and
inverse checkered patterns to the display. Each pattern is dis-
played for approximately 2.0 seconds. During the self test func-
tion the display must not be accessed. The time needed to
execute the self test function is calculated by multiplying the
clock time by 262,144 (typical time ≈ 4.6 sec.). At the end of the
self test function, the Character RAM is loaded with blanks; the
Control Word Register is set to zeroes except D5, and the
Flash RAM is cleared and the UDC Address Register is set to
all 1.0 s.
Clear Function (see Figures 13 and 14)
Control Word bit, D7 clears the character RAM to 20 hex and
the flash RAM to all zeroes. The RAMs are cleared within three
clock cycles (110 µs minimum, using the internal clock) when
D7 is set to 1. During the clear time the display must not be
accessed. When the clear function is finished, bit 7 of the
Control Word RAM will be reset to a “0”.
Reset Function
The display should be reset on power up of the display
(RST=LOW). When the display is reset, the Character RAM,
Flash RAM, and Control Word Register are cleared.
The display's internal counters are reset. Reset cycle takes
three clock cycles (110 µseconds minimum using the internal
clock). The display must not be accessed during this time.
To synchronize the flashing and blinking of multiple displays, it
is necessary for the display to use a common clock source and
reset all the displays at the same time to start the internal
counters at the same place.
While RST is low, the display must not be accessed by RD
nor WR.
Figure 11. Flash RAM Access Logic
RST CE WR RD FL A4 A3 A2 A1 A0
1
00
1 0 X X Flash RAM Address for Digits 0–7
1
01
0 0 X X Flash RAM Address for Digits 0–7
D7 D6 D5 D4 D3 D2 D1 D0
D0=Flash Data, 0-Flash Off and 1=Flash On
(Write Cycle)
D0=Flash Data, 0-Flash Off and 1=Flash On
(Read Cycle)
Figure 12. Control Word Access Logic
RST CE WR RD FL A4 A3
1
00
1110
A2 A1 A0
Not used for Control Word
1
01
0 1 1 0 Not used for Control Word
D7 D6 D5 D4 D3 D2 D1 D0
Control Word data for a Write Cycle,
see Figure 13
Control Word data for a Read during a
Read Cycle
 2000 Infineon Technologies Corp. • Optoelectronics Division • San Jose, CA
www.infineon.com/opto • 1-888-Infineon (1-888-463-4636)
OSRAM Opto Semiconductors GmbH & Co. OHG • Regensburg, Germany
www.osram-os.com • +49-941-202-7178
10
HDSP2110S/1S/2S/3S/4S/5S
March 24, 2000-13