English
Language : 

ICS98ULPA877A Datasheet, PDF (5/14 Pages) Integrated Device Technology – 1.8V Low-Power Wide-Range Frequency Clock Driver
ICS98UL PA8 77A
Advance Information
Recommended Operating Condition (see note1)
Commercial: TA = 0°C - 70°C; Industrial: TA = -40°C - +85°C;
Supply Voltage AVDDQ, VDDQ = 1.8 V +/- 0.1V (unless otherwise stated)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX UNITS
Supply Voltage
Low level input voltage
High level input voltage
DC input signal voltage
(note 2)
Differential input signal
voltage (note 3)
VDDQ, AVDD
1.7
1.8
1.9
V
CLK_INT, CLK_INC, FB_INC,
VIL FB_INT
0.35 x VDDQ V
OE, OS
0.35 x VDDQ V
VIH
CLK_INT, CLK_INC, FB_INC,
FB_INT
0.65 x VDDQ
V
OE, OS
0.65 x VDDQ
V
VIN
-0.3
VDDQ + 0.3
V
DC - CLK_INT, CLK_INC,
0.3
VID
FB_INC, FB_INT
AC - CLK_INT, CLK_INC,
0.6
FB_INC, FB_INT
VDDQ + 0.4
V
VDDQ + 0.4
V
Output differential cross-
voltage (note 4)
VOX
Input differential cross-
voltage (note 4)
VIX
VDDQ/2 - 0.10
VDDQ/2 + 0.10 V
VDDQ/2 - 0.15 VDD/2 VDDQ2 + 0.15 V
High level output current
IOH
Low level output current
IOL
Operating free-air
temperature
TA
-9
mA
9
mA
-40
85
°C
Notes:
1. Unused inputs must be held high or low to prevent them from floating.
2. DC input signal voltage specifies the allowable DC execution of differential input.
3. Differential inputs signal voltages specifies the differential voltage [VTR-VCP]
required for switching, where VTR is the true input level and VCP is the
complementary input level.
4. Differential cross-point voltage is expected to track variations of VDDQ and is the
voltage at which the differential signal must be crossing.
1177C—05/23/07
5