English
Language : 

ICS621 Datasheet, PDF (3/10 Pages) Integrated Device Technology – LOW SKEW 1 TO 4 CLOCK BUFFER
ICS621
LOW SKEW 1 TO 4 CLOCK BUFFER
FAN OUT BUFFER
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS621. These ratings, which are
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these
or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Item
Supply Voltage, VDD
Output Enable and All Outputs
ICLK
Ambient Operating Temperature (industrial)
Ambient Operating Temperature (commercial)
Storage Temperature
Junction Temperature
Soldering Temperature
Rating
5V
-0.5 V to VDD+0.5 V
-0.5 V to 3.6 V (VDD > 0V)
-40 to +85 °C
0 to +70 °C
-65 to +150°C
125°C
260°C
Recommended Operation Conditions
Parameter
Ambient Operating Temperature (industrial)
Ambient Operating Temperature (commercial)
Power Supply Voltage (measured in respect to GND)
Min.
-40
0
1.14
Typ.
Max.
+85
+70
1.89
Units
°C
°C
V
IDT™ / ICS™ LOW SKEW 1 TO 4 CLOCK BUFFER
3
ICS621
REV B 030907