English
Language : 

ICS2059-02 Datasheet, PDF (8/11 Pages) Integrated Circuit Systems – Clock Multiplier and Jitter Attenuator
ICS2059-02
Clock Multiplier and Jitter Attenuator
Recommended Operation Conditions
Parameter
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Min.
-40
+3.15
Typ.
+3.3
Max.
+85
+3.45
Units
°C
V
DC Electrical Characteristics
Unless stated otherwise, VDD = 3.3 V ±5%, Ambient Temperature -40 to +85°C
Parameter
Symbol
Conditions
Min. Typ. Max. Units
Operating Voltage
VDD
3.15 3.3 3.45
V
Supply Current
IDD Clock outputs
unloaded, VDD = 3.3 V
10
15
mA
Input High Voltage, SEL1
VIH
Input Low Voltage, SEL1
VIL
Input High Voltage, ISEL,
VIH
SEL0
VDD-0.5
2
V
0.5
V
V
Input Low Voltage, ISEL, SEL0 VIL
Input High Voltage, ICLK1, 2
VIH
Input Low Voltage, ICLK1, 2
VIL
Input High Current
IIH
VIH = VDD
Input Low Current
IIL
VIL = 0
Input Capacitance, except X1
CIN
Output High Voltage (CMOS
Level)
VOH IOH = -4 mA
0.8
V
VDD/2+1
V
VDD/2-1 V
-10
+10
µA
-10
+10
µA
7
pF
VDD-0.4
V
Output High Voltage
Output Low Voltage
Short Circuit Current
VIN, VCXO Control Voltage
Nominal Output Impedance
VOH
VOL
IOS
VXC
ZOUT
IOH = -8 mA
IOL = 8 mA
2.4
V
0.4
V
±50
mA
0
VDD
V
20
Ω
MDS 2059-02 C
8
Revision 031605
Integrated Circuit Systems, Inc. ● 525 Race Street, San Jose, CA 95126 ● tel (408) 297-1201 ● www.icst.com