English
Language : 

ICS932S200 Datasheet, PDF (7/12 Pages) Integrated Circuit Systems – Frequency Timing Generator for Dual Server/Workstation Systems
ICS932S200
Absolute Maximum Ratings
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . 7.0 V
Logic Inputs . . . . . . . . . . . . . . . . . . . . . . . . . GND –0.5 V to VDD +0.5 V
Ambient Operating Temperature . . . . . . . . . . 0°C to +70°C
Storage Temperature . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These
ratings are stress specifications only and functional operation of the device at these or any other conditions above those
listed in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions
for extended periods may affect product reliability.
Electrical Characteristics - Input/Supply/Common Output Parameters
TA = 0 - 70º C; Supply Voltage VDD = 3.3 V +/-5%, VDDL = 2.5 V +/-5% (unless otherwise stated)
PARAMETER SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Input High Voltage
Input Low Voltage
Input High Current
Input Low Current
Input Low Current
Operating
Supply Current
VIH
2
VDD+0.3 V
VIL
VSS-0.3
0.8
V
IIH
VIN = VDD
0.1
5
µA
IIL1
VIN = 0 V; Inputs with no pull-up resistors -5
2.0
µA
IIL2 VIN = 0 V; Inputs with pull-up resistors
-200 -100
µA
IDD3.3OP100 Select @ 100MHz; Max discrete cap loads
IDD3.3OP133 Select @ 133MHz; Max discrete cap loads
70 160
mA
80
Power Down
Supply Current
IDD3.3PD CL =30 pF; PWRDWN# = 0
102 200 uA
Input frequency
Input Capacitance1
Fi
VDD = 3.3 V
CIN Logic Inputs
Transition Time1
Settling Time1
Clk Stabilization1
CINX
TTrans
TS
TStab
X1 & X2 pins
To 1st crossing of target Freq.
From 1st crossing to 1% target Freq.
From VDD = 3.3 V to 1% target Freq.
1Guaranteed by design, not 100% tested in production.
12 14.32 16
5
27 36 45
3
1
3
MHz
pF
pF
ms
ms
ms
Electrical Characteristics - Input/Supply/Common Output Parameters
TA = 0 - 70º C; Supply Voltage VDD = 3.3 V +/-5%, VDDL = 2.5 V +/-5% (unless otherwise stated)
PARAMETER SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Operating
Supply Current
IDD2.5OP100 Select @ 100MHz; Max discrete cap loads
IDD2.5OP133 Select @ 133MHz; Max discrete cap loads
38 75
mA
69 90
1Guaranteed by design, not 100% tested in production.
0427C—07/03/02
7