English
Language : 

ICS9248-134 Datasheet, PDF (5/13 Pages) Integrated Circuit Systems – Frequency Timing Generator for PENTIUM II/III Systems
ICS9248-134
Absolute Maximum Ratings
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Logic Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND –0.5 V to VDD +0.5 V
Ambient Operating Temperature . . . . . . . . . . . . 0°C to +70°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Case Temperature . . . . . . . . . . . . . . . . . . . . . . . . 115°C
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These ratings are
stress specifications only and functional operation of the device at these or any other conditions above those listed in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may affect product reliability.
Electrical Characteristics - Input/Supply/Common Output Parameters
TA = 0 - 70º C; VDD = 3.3 V +/-5%; VDDL = 2.5 V +/-5% (unless otherwise stated)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Input High Voltage
VIH
Input Low Voltage
VIL
Input High Current
IIH
VIN = VDD
Input Low Current
IIL1
VIN = 0 V; Inputs with no pull-up resistors
Input Low Current
IIL2
VIN = 0 V; Inputs with pull-up resistors
Operating
IDD3.3OP100 CL = 0 pF; Select @ 100 MHz
Supply Current
IDD3.3OP133 CL = 0 pF; Select @ 133 MHz
Input frequency
Input Capacitance1
Fi
VDD = 3.3 V;
CIN
Logic Inputs
Transition Time1
Settling Time1
Clk Stabilization1
CINX
Ttrans
Ts
TSTAB
X1 & X2 pins
To 1st crossing of target Freq.
From 1st crossing to 1% target Freq.
From VDD = 3.3 V to 1% target Freq.
1Guaranteed by design, not 100% tested in production.
2
VSS-0.3
-5
-200
11
27
VDD+0.3
0.8
0.1
5
2.0
-100
71
160
76
160
14.318 16
5
36
45
3
5
3
V
V
µA
µA
µA
mA
mA
MHz
pF
pF
ms
ms
ms
Electrical Characteristics - Input/Supply/Common Output Parameters
TA = 0 - 70º C; VDD = 3.3 V +/-5%; VDDL = 2.5 V +/-5% (unless otherwise stated)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Operating
Supply Current
Power Down
Supply Current
IDD2.5OP100
IDD2.5OP133
IDD2.5PD
CL = 0 pF; Select @ 100 MHz
CL = 0 pF; Select @ 133 MHz
CL = 0 pF; PWRDWN# = 0
15
75
mA
18
90
mA
272 400 µA
1Guaranteed by design, not 100% tested in production.
5