English
Language : 

ICS9112-06 Datasheet, PDF (3/8 Pages) Integrated Circuit Systems – Low Skew Output Buffer
ICS9112-06/07
Absolute Maximum Ratings
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 7.0 V
Logic Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND –0.5 V to VDD +0.5 V
Ambient Operating Temperature . . . . . . . . . . . . 0°C to +70°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These ratings are
stress specifications only and functional operation of the device at these or any other conditions above those listed in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods
may affect product reliability.
Electrical Characteristics at 3.3V
VDD = 3.0 – 3.7 V, TA = 0 – 70° C unless otherwise stated
DC Characteristics
PARAMETER
Input Low Voltage
Input High Voltage
Input Low Current
Input High Current
Output Low Voltage1
Output High Voltage1
Power Down Supply
Current
Supply Current
SYMBOL
VIL
VIH
IIL
IIH
VOL
VOH
IDD
IDD
TEST CONDITIONS
VIN=0V
VIN=VDD
IOL = 8mA
IOH = 8mA
REF = 0 MHz
Unloaded oututs at 66.66 MHz SEL
inputs at VDD or GND
MIN
2.0
2.4
TYP
MAX
0.8
19
50.0
0.10
100.0
0.25
0.4
2.9
37.0
75.0
16.0
40.0
Notes:
1. Guaranteed by design and characterization. Not subject to 100% test.
2. All Skew specifications are mesured with a 50Ω transmission line, load teminated with 50Ω to 1.4V.
3. Duty cycle measured at 1.4V.
4. Skew measured at 1.4V on rising edges. Loading must be equal on outputs.
UNITS
V
V
µA
µA
V
V
µA
mA
3