English
Language : 

X25256 Datasheet, PDF (9/17 Pages) IC MICROSYSTEMS – 5MHz SPI Serial E 2 PROM with Block Lock ™ Protection
X25256 – Preliminary Information
ABSOLUTE MAXIMUM RATINGS
Temperature under bias........................–65 to +135°C
Storage temperature .............................–65 to +150°C
Voltage on any pin with
respect to V SS ......................................... –1V to +7V
D.C. output current
5mA (soldering, 10 seconds) ......................... 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; and the functional operation of
the device (at these or any other conditions above
those indicated in the operational sections of this speci-
fication) is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device
reliability.
Supply Voltage
X25256-2.5
Limit
2.5V to 5.5V
D.C. OPERATING CHARACTERISTICS(Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC
VCC Supply Current (Active)
ISB
ILI
ILO
VIL(1)
VIH(1)
VOL1
VOH1
VOL2
VOH2
VCC Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Limits
Min.
Max.
5
1
–1
VCC x 0.7
VCC–0.8
VCC–0.4
10
10
VCC x 0.3
VCC + 0.5
0.4
0.4
Unit
mA
µA
µA
µA
V
V
V
V
V
V
Test Conditions
SCK = VCC x 0.1/VCC x 0.9 @ 5MHz, SO =
Open, CS = VSS
CS = VCC, VIN = VSS or VCC – 0.3V,
TA = 25°C
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA, VCC = 5V
IOH = –1.0mA, VCC = 5V
IOL = 1.0mA, VCC = 3V
IOH = –0.4mA, VCC = 3V
POWER-UP TIMING
Symbol
TPUR(3)
TPUW(3)
Parameter
Power-up to Read Operation
Power-up to Write Operation
Min.
Max.
Unit
1
ms
5
ms
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
CI/O(3)
C IN(3)
Parameter
Output Capacitance (SO)
Input Capacitance (SCK, SI, CS, WP, HOLD)
Max.
8
6
Unit
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
Notes: (1)VIL min. and VIH max. are for reference only and are not tested.
(2)This parameter is periodically sampled and not 100% tested.
(3)tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters are
periodically sampled and not 100% tested.
www.icmic.com
Characteristics subject to change without notice. 9 of 17