English
Language : 

X25642 Datasheet, PDF (8/16 Pages) Xicor Inc. – Advanced SPI Serial E 2 PROM with Block Lock TM Protection
X25642
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias....................–65°C to +135°C
Storage Temperature ........................–65°C to +150°C
Voltage on any Pin with Respect
to VSS .........................................................–1V to +7V
D.C. Output Current ............................................. 5mA
(Soldering, 10 seconds) ..............................300°C
RECOMMENDED OPERATING CONDITIONS
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
Temperature
Commercial
Industrial
Military
Min.
0°C
–40°C
–55°C
Max.
+70°C
+85°C
+125°C
7037 FRM T06
Supply Voltage
X25642
X25642-2.7
Limits
5V ±10%
2.7V to 5.5V
7037 FRM T07
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC
ISB
ILI
ILO
VIL(1)
VIH(1)
VOL1
VOH1
VOL2
VOH2
VCC Supply Current (Active)
VCC Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Limits
Min.
Max.
5
1
10
10
–1
VCC x 0.3
VCC x 0.7 VCC + 0.5
0.4
VCC–0.8
0.4
VCC–0.3
Units
Test Conditions
mA SCK = VCC x 0.1/VCC x 0.9 @ 2MHz,
µA CS = VCC, VIN = VSS or VCC – 0.3V
µA VIN = VSS to VCC
µA VOUT = VSS to VCC
V
V
V IOL = 3mA, VCC = 5V
V IOH = –1.6mA, VCC = 5V
V IOL = 1.5mA, VCC = 3V
V IOH = –0.4mA, VCC = 3V
7037 FRM T08
POWER-UP TIMING
Symbol
TPUR(3)
TPUW(3)
Parameter
Power-up to Read Operation
Power-up to Write Operation
Min.
Max.
1
1
Units
ms
ms
7037 FRM T09
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
Parameter
CI/O(3)
CIN(3)
Output Capacitance (SO)
Input Capacitance (SCK, SI, CS, WP, HOLD)
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
7037 FRM T10
Notes: (1) VIL min. and VIH max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
(3) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These
parameters are periodically sampled and not 100% tested.
8