English
Language : 

IC-MA_14 Datasheet, PDF (8/19 Pages) IC-Haus GmbH – 8-BIT ANGULAR HALL SENSOR / ENCODER
iC-MA
8-BIT ANGULAR HALL SENSOR / ENCODER
OPERATING REQUIREMENTS: Logic
Operating conditions: VDD = 5 V ±10 %, Tj = -40...125 °C, unless otherwise noted
Input level low = 0...0.45 V, high = 2.4 V...VDD, timing according Figure 2
Item Symbol Parameter
No.
Conditions
Logic
I001 ts(NEN) Setup Time NEN
CLK: low → high (see Figure 11)
I002 tp(NEN) Delay Time NENO
CLK: high → low (see Figure 11)
I003 tp(SIG1) Delay Time SIG1
CL() = 50 pF (see Figure 11)
I004 tp(SIG2) Delay Time SIG2
CL() = 50 pF (see Figure 11)
I005 tp(CFGx) Setup Time at CFGx, x = 1..3
see Figure 5
V
2.4V
2.0V
Input/Output
0.8V
0.45V
t
1
0
Figure 2: Reference levels for delays
Rev C1, Page 8/19
Min.
30
Unit
Max.
ns
30
ns
60
µs
2
µs
10
µs