PROGRAMMING THE CONFIGURATION
Rev C1, Page 10/19
iC-MA has 28 modes of operation (see tables on the
following pages). After the device has been switched
on or woken up from standby mode by a low signal at
pin NEN the levels at the conï¬guration inputs CFG1 to
CFG3 are assessed. These three-level inputs can be
connected to GND = low level, left open = open or con-
nected to VDD = high level. For correct identiï¬cation,
a setup time of at least tp(CFGx) = 4 µs must be main-
tained between programming the conï¬guration and ac-
tivating the device. While the device is active changes
in signal at the conï¬guration inputs are ignored.
In standby all ports are switched to tristate, i.e. high
impedance. Only in chain operation modes port D level
is active high so that the devices arranged further be-
hind can also be deactivated.
4V
VDD
NEN
iC-MA active
iC-MA active
If several iC-MAs are connected in series in chain op-
eration (see the description of functions on page 14)
it must be ensured that the NEN input of the devices
level is switched to low during the various clock cy-
cles and that the programming default does thus not
lie within the active phase of the devices.
CFGx
td(VDD)on
tp(CFGx)
tp(CFGx)
Figure 5: Programming the conï¬guration
|
▷ |