IC-NE Datasheet, PDF (6/9 Pages) IC-Haus GmbH – LIGHT-GRID PULSE RECEIVER | |||
|
◁ |
iC-NE
LIGHT-GRID PULSE RECEIVER
Rev E1, Page 6/9
I(PD)
I(PD)pk
2
I(PD)pk
tr
I(SP)
âI(SN)
Ipnpk
t
t whi
t wpk
tf
Offset (= IO*ISUM)
t
may be positive or negative
Figure 3: Differential output current
pulse at SP and SN versus
input current pulse at PD
CLK
DIN
Q1
Q2
Q3
DOUT
EN1
INH= Q1
I(PD)
V(SP)
V(SN)
1st
2nd
t en
t inh
t p ( ) IDCon
t wlo
t whi
t p ( ) IDCoff
Figure 4: Timing characteristics (analogue section), outputs SP and
SN with resistors to VDD
VDD
5V
RA
100kâ¦
CA
10uF
1 DIN
2 VDD
INH EN
I(PD)dc
PD
8
RGen
uA
adjust VS for I(PD)dc= â15uA
GND 7
500kâ¦
mA ISUM
VRR
4V+RL*ISUM/2
VS
approx. â6V
adjust until ISUM stops rising
3
6
CLK
DOUT
RL
RL
Differential
4 SP
SN 5
1k⦠1kâ¦
Amplifier
â
R1
C2
iCâNE
+
Gain=10
BW= 10MHz
110â¦
330pF
C1
1.2nF
R2
10kâ¦
V RMSâ
Voltmeter
Figure 5: Noise measurement circuit
OPERATING REQUIREMENTS: Logic
Operating Conditions: VDD = 5 V ±10%, Ta = 0...70 °C, CL() = 50 pF,
input levels lo = 0...0.45 V, hi = VDD â 0.45 V...VDD, see Fig. 1 for reference levels and waveforms
Item Symbol Parameter
No.
Conditions
I001 ten
Activation Time:
DIN lo â hi to CLK lo â hi
Standby to ampliï¬er operation (see Fig. 4)
I002 tinh
Output Activation Time:
1st CLK lo â hi until output ready to
report
Sufï¬cient decay of transient differential output
current: |I(SN) â I(SP) â IO â ISUM| ⤠20 µA
(see Fig. 4)
I003 tset
Setup time:
DIN stable before CLK lo â hi
(see Fig. 2)
I004 thold
Hold time:
DIN stable after CLK lo â hi
(see Fig. 2)
I005 fo
Permissible Frequency at CLK
Min.
10
5
50
50
Unit
Max.
µs
µs
ns
ns
10
MHz
|
▷ |