English
Language : 

IC-NE Datasheet, PDF (5/9 Pages) IC-Haus GmbH – LIGHT-GRID PULSE RECEIVER
iC-NE
LIGHT-GRID PULSE RECEIVER
Rev E1, Page 5/9
ELECTRICAL CHARACTERISTICS
Operating Conditions: VDD = 5 V ±10%, V(SN, SP) = VDD − 2 V...VDD, Tj = -20...85 °C, unless otherwise stated
Item Symbol Parameter
No.
Conditions
Min. Typ.
118 Ipn()
Differential Output Current
Ipn() = I(SN) − I(SP);
I(PD)pk = -10 µA (see Fig. 3)
-7.0 -5.0
119 Ipn()
Differential Output Current
Ipn() = I(SN) − I(SP);
I(PD)pk = -100 µA (see Fig. 3)
-9.7 -7.3
120 INoise
Differential Output Current Noise I(PD)dc = -15 µA, Rgen = 500 kΩ, no additional
5
(RMS)
filter, Tj = 27 °C (see Fig. 5)
121 INoise
Differential Output Current Noise I(PD)dc = -15 µA, Rgen = 500 kΩ, with BP-filter
3.5
(RMS)
50 kHz...1.2 MHz, Tj = 27 °C (see Fig. 5)
122 tp()IDCon Output Stage Turn-on Delay: I(PD)dc = -15 µA...0, I(PD)ac = 0 (see Fig. 4)
CLK lo → hi to 90% I(SN), I(SP)
123 tp()IDCoff Output Stage Turn-off Delay: I(PD)dc = -15 µA...0, I(PD)ac = 0 (see Fig. 4)
CLK lo → hi to 10% I(SN), I(SP)
Control Inputs DIN, CLK
201 Vt()hi
Threshold Voltage hi
202 Vt()lo
Threshold Voltage lo
33
203 Vhys()
Schmitt-Trigger Input Hysteresis
400
204 Ipd()
Pull-Down Current
V() = 1 V...VDD
Tj = 27 °C
3
6
Output Buffer DOUT
301 Vs()hi
Saturation Voltage hi
Vs()hi = VDD − V(DOUT); I() = -4 mA
302 Vs()lo
Saturation Voltage lo
I() = 4 mA
303 Isc()hi
Short-Circuit Current hi
V() = 0 V
Tj = 27 °C
-100
-40
304 Isc()lo
Short-Circuit Current lo
V() = VDD
Tj = 27 °C
25
40
305 tr()
Rise Time
CL() = 50 pF
Tj = 27 °C
20
306 tf()
Fall Time
CL() = 50 pF
Tj = 27 °C
20
Timing Characteristics
401 tplh(CLK- Propagation Delay:
CL(DOUT) = 50 pF (see Fig. 2)
DOUT) CLK hi → lo until DOUT lo → hi Tj = 27 °C
26
402 tphl(CLK- Propagation Delay:
CL(DOUT) = 50 pF (see Fig. 2)
DOUT) CLK hi → lo until DOUT hi → lo Tj = 27 °C
25
Unit
Max.
-3.0 mA
-4.0 mA
µA
µA
3.0
µs
3.0
µs
66 %VDD
%VDD
mV
12
µA
µA
0.4
V
0.4
V
-25 mA
mA
100 mA
mA
60
ns
ns
60
ns
ns
60
ns
ns
60
ns
ns
V
VDD−0.45V
Vt()hi
Input/Output
Vt()lo
0.45V
t
1
0
Figure 1: Reference levels
CLK
DIN
Q1
t set (DIN)
t hold (DIN)
Q2
Q3
DOUT
t plh (CLK−DOUT)
Figure 2: Timing characteristics
t phl (CLK−DOUT)